Advantech EKI-2712G-4FPI-AE Bruksanvisning
Les nedenfor 📖 manual på norsk for Advantech EKI-2712G-4FPI-AE (3 sider) i kategorien Bryter. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/3
EKI-2712G-4FPI
Unmanaged Redundant Industrial Switch
The -2712G-4FPI is a new generation of EKI
unmanaged switches. With 8 RJ-45 and 4 SFP
ports, they provide up to 30 watts per port to fulll
high power consumption PD (Power Device)
requirements.
Before installation, please make sure that you
have received the following:
•
1 x EKI-2712G-4FPI Unmanaged Switch
•
1 x Wall mounting bracket with screws
•
1 x DIN-rail Mounting Bracket and Screws
•
1 x Startup manual
•
If anything is missing or damaged, contact your
distributor or sales representative immediately.
For more detailed information, please refer to the
full manual which can be found on the Advan-
tech’s website.
General
•
Compatibility: IEEE 802.3, 802.3u, 802.3x,
802.3az, 802.3ab
•
LAN: 10/100/1000 Base- TX
•
SFP: Up to 110 km (depends on SFP)
•
Ethernet RJ-45 Distance: Up to 100 m
•
Connectors:
8 x 10/100/1000Base- - T/TX RJ 45
4 x SFP (mini-GBIC)
•
Switch Architecture: Store and Forward
•
Power Requirements: 48~55 V
DC, redundant
Power Input with reverse polarity protection.
•
Power Consumption: 15 Watts Max. @48V
DC
(System)
•
Power Budget: 120W
•
Dimensions (W x H x D): 74 x 152 x 105 mm
•
Enclosure: IP30
•
Operating Temperature:
-40 ~ 75°C (-40 ~ 167°F)
•
Storage Temperature: -40 ~ 85°C
(-40°F ~ 185°F)
•
Operating Humidity: 10 ~ 95%
(non-condens- ing)
•
Storage Humidity : 0 ~ 95%(non-condensing)
•
Safety: UL61010
• EMC: CE, FCC Class A
•
Warranty: 5 years
•
Altitude: up to 2000 m
Specications
Overview
Packing List
User Manual
STARTUP MANUAL
EKI-2712G- Startup Manual 14FPI
Company Address
ADVANTECH CO., LTD. (研華股份有限公司)
No.1, ALLEY 20, LANE 26, RUEIGUANG RD,
NEIHU DISTRICT, TAIPEI 114. TAIWAN
Notes
For more information on this and other Advantech
products, please visit our websites at:
http://www.advantech.com/products/unmanaged-
industrial ethernet- -switches/sub_1-2mlk0j
For technical support and service:
http://www.advantech.com/support/
This startup manual is for EKI-2712G-4FPI
1 st Edition
June 2018
EKI-2712G- 4FPI
Warning! Do not block air ventilation holes.
Avertissement ! Ne bouchez pas les orices
de ventilation
Warning! Use dry cloth for cleaning
Avertissement ! Nettoyez avec un chion
sec
Warning! This is open type equipment and should be
installed in a suitable enclosure
Avertissement ! Cet appareil est de type
ouvert. Il doit être installé dans une
enceinte appropriée
Installing on the DIN rail
WARNING!
1.
Insert the top back of the mounting bracket over the
DIN rail.
2.
Push the bottom of the switch towards the DIN rail until
it snaps into place.
Removing from the DIN-Rail
1.
Push the switch down to free the bottom of the plate
from the DIN rail.
2.
Rotate the bottom of the device towards you and away
from the DIN rail.
3.
Once the bottom is clear of the DIN rail lift the device
straight up to unhook it from the DIN rail.
Wall Mounting
1.
Secure the wall mounting plates to the wall .
Minimum safe height : Up 10 cm/ Down 10 cm
2.
Slide the EKI onto the mounting plates.
Minimum safe height : Up 10 cm/ Down 10 cm
Mounting
Overview
EKI-2712G- 24FPI Startup Manual
The switche support dual +48~55V DC power inputs.
1.
Power inputs 48~55VDC, 5.5A PoE out max 0.5A per
port.
2.
Tighten wire-clamps to prevent the DC wires from
loosening.
3.
P- alarm Fail linking to closed loop device, such as
system, for transmit signals only.
WARNING
Take into consideration the following guidelines before
wiring the device
Tenez compte des directrices suivantes avant de
câbler l’appareil
•
The terminal block (CN1) is suitable for 12-24 AWG
(7A). Torque value 7 lb-in.
•
Le bornier (CN1) est conçu pour des ls de calibre
américain (AWG) 17 à 24 (7A). Couple de serrage :
0,8 N•m (7 lb•in).
•
The cross sectional area of the earthing conductors
should be at least 0.205 mm.
•
La section des ls de mise à la terre doit être d’au
moins 0,205 mm.
•
The temperature rating of the input connection
cable should higher than 90°C.
•
La température de service nominale du câble
d’entrée doit être supérieure à 90 °C
The switches support dual +48~55V DC power inputs.
1. The switches can be powered by using SELV +48~55V
DC. All circuits should be connected to a SELV circuit.
1. Les commutateurs peuvent être alimentés en courant
continu TBTS de +48 à 55 V. Tous les circuits doivent
être raccordés à un circuit TBTS.
2. Make sure the voltage of the power source is correct
before connecting the equipment to the power discon-
nect
2. Vérifiez que la tension de la source d’alimentatio n soit
la correcte avant de brancher l’appareil sur le
disjoncteur de l’alimentation.
3. If the equipment is not used for a long time remove it
from the power source to avoid damage by transient
over voltage.
3. débranchez Si l’appareil va rester longtemps inactif, -
le de la source d’alimentation pour éviter tous
dommages dus à des surtensions transitoires.
4. For use pollution degree 2 environments and indoor use.
4. N’utilisez l’appareil qu’à l’intérieur ou dans des
environnements à degré de pollution classe 2.
5. If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the equip-
ment may be impaired.
5. Si l’appareil est utilisé d’une manière non spéciée par
le fabricant, la protection qu’il apporte peut se voir
diminuée.
Before installing the device, power on the switch to verify
that the switch passes the power on self- -test (POST). To
connect the cabling to the power source see “Power Supply
Installation”
At startup (POST), the system LED blinks green, while the
remaining LEDs are a solid green. Once the switch passes
POST self-test, the system LED turns green. The other
LEDs turn o and return to their operating status. If the
switch fails POST, the system LED switches to an amber
state.
After a successful self-test, power down and disconnect the
power cabling. The switch is now ready for installation to its
nal location
Safety Instructions
Power/Grounding Connection
Verifying Switch Operation
EKI-2712G- 34FPI Startup Manual
Produkspesifikasjoner
Merke: | Advantech |
Kategori: | Bryter |
Modell: | EKI-2712G-4FPI-AE |
Trenger du hjelp?
Hvis du trenger hjelp med Advantech EKI-2712G-4FPI-AE still et spørsmål nedenfor, og andre brukere vil svare deg
Bryter Advantech Manualer
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
Bryter Manualer
- Bryter D-Link
- Bryter Lancom
- Bryter IFM
- Bryter TP Link
- Bryter Totolink
- Bryter StarTech.com
- Bryter Yamaha
- Bryter Extron
- Bryter Lindy
- Bryter Netgear
- Bryter Digitus
- Bryter Panasonic
- Bryter LevelOne
- Bryter EMOS
- Bryter CSL
- Bryter Smart-AVI
- Bryter Generac
- Bryter Dahua Technology
- Bryter Equip
- Bryter Speaka
- Bryter Nedis
- Bryter Alcatel
- Bryter Atlona
- Bryter Crestron
- Bryter PureLink
- Bryter Kramer
- Bryter ATen
- Bryter Blustream
- Bryter WHALE
- Bryter Tenda
- Bryter Suevia
- Bryter ZyXEL
- Bryter Homematic IP
- Bryter Vimar
- Bryter Setti+
- Bryter Intellinet
- Bryter IOGEAR
- Bryter Kaiser
- Bryter Finder
- Bryter Hager
- Bryter DEHN
- Bryter Berker
- Bryter Brilliant
- Bryter Roline
- Bryter QNAP
Nyeste Bryter Manualer
4 Januar 2025
3 Januar 2025
3 Januar 2025
2 Januar 2025
2 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
1 Januar 2025
31 Desember 2025