MODELS L2000L • L3500EXL
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and
requirements.
LOSONE SELECT® IN-LINE
CABINET VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
MOUNTING
CHANNELS
Factory shipped ready to be installed as a ceiling
ventilator with right-angle discharge.
MOUNTING (In-line Configuration)
Converted for in-line applications.
EXHAUST
CEILING
3/8” MIN.
THREADED ROD
(By Others)
ACCESS
PANEL
DUCT
FLANGES INTAKE
GRILLE KIT
EXHAUST
3/8” MIN.
THREADED ROD
(By Others)
ACCESS
PANEL
DUCT
FLANGES
ADJUSTABLE
BRACKET
INTAKE
INTAKE
PLAN INSTALLATION
MOUNTING (Right-angle Discharge)
!
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45o45o
NOT FOR USE IN
A COOKING AREA.

MODELS L2000L • L3500EXL
Page 2
PLAN INSTALLATION (cont.) MOUNTING OPTIONS
CONVERTING FROM RIGHT-ANGLE TO IN-LINE
Remove and reverse duct anges and access panel
positions on housing.
For correct intake and exhaust duct size, see Table 1.
TABLE 1
ACCESS
PANEL
INTAKE DUCT
FLANGES
EXHAUST
DUCT FLANGE
EXHAUST
DUCT FLANGE
Typical mounting with threaded rod through
mounting channels on top of housing.
3/8” MIN.
THREADED RODS
(By Others)
DIM. L2000L L3500EXL
C 12-5/8” 12-5/8”
D 39-5/8” 47-3/8”
Mounting with threaded rod through adjustable
mounting brackets located at top of housing.
3/8” MIN. THREADED RODS
(By Others)
DIM. L2000L L3500EXL
A 7-3/4” 10-1/4”
B 33-3/4” 41-3/4”
Mounting with threaded rods through adjustable
mounting brackets located at bottom of housing.
Mounting brackets can be bolted to housing ends in a variety of
configurations. Use screws and nuts provided in parts bag.
If installing unit as a ceiling ventilator, make sure that either duct
flanges or housing will be flush with finished ceiling. Duct flanges may
be removed and discarded if they interfere with a ceiling installation.
MOUNTING OPTIONS
MODEL INTAKE DUCT SIZE EXHAUST DUCT SIZE
L2000L 12-3/8” x 35-3/4” 7-3/4” x 33-3/4”
L3500EXL 14-1/2” x 43-1/2” 9-3/4” x 41-3/8”
Provide solid support to minimize sound leves. There are two basic
mounting methods for these units.

Page 3
MODELS L2000L • L3500EXL
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove
grille and clean with a soft cloth and mild soap or detergent. Dry
grille thoroughly before reinstalling.
To clean blower assembly: Remove either access panel or ceiling
grille. Unplug blower assembly. Provide safe support for blower as-
sembly. Remove blower mounting screws and lift blower assembly
out of housing. Gently vacuum housing and blower motor. Vacuum or
gently wash blower wheels and housings. DO NOT ALLOW WATER
TO ENTER MOTOR. Make sure blower assembly is completely dry
before reinstalling. Replace blower assembly in housing and plug
assembly in. Replace grille and/or access panel.
Motor is permanently lubricated. Do not oil or disassemble motor.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may
be controlled using an on/off switch or a solid-state, variable speed
control. Follow wiring instructions packed with control, and adhere
to all local and state codes, and the National Electrical Code.
MOUNTING OPTIONS
EXHAUST
ACCESS
PANEL
INTAKE
SLEEPER
1-1/4”
Typical wall mounting with 3/8” threaded fasteners
(by others) through mounting brackets.
Connect electrical power cable to housing with proper connector for
type of cable used. Provide 6” leads inside wiring box.
ELECTRICAL CONNECTIONS
MOTORMOTOR
MOTOR
MODEL
L3500EXL
MODEL
L2000L
SPEED CONTROL
OR SWITCH
SPEED CONTROL
OR SWITCH
LINE IN
120 VAC
60 HZ
LINE IN
240 VAC
60 HZ
1 PHASE
WHITE
GND
BLK
RED
GND
BLK
ACCESSORY INSTALLATIONS
Install damper ap using rod provided.
Snap screw bushings into square openings around intake
opening. Install grille with screws provided.
NOTE: If duct flanges around intake opening interfere with instal-
lation, remove them. Make sure that housing is flush with finished
ceiling when ventilator is mounted.
OUTSIDE
DAMPER BUSHING
(Snaps over rod)
INSIDE DAMPER
BUSHING
(Inside of frame)
DAMPER FLAP
(Should open freely)
CABINET FLUSH
CEILING
GRILLE
NUTS
GRILLE
SCREWS
If ventilator will discharge directly outside, install adamper kit to
prevent backdrafts. A grille kit is available for applications where
ventilator is installed with direct or remote room air intake.
ROD
(Inserts into inside bushing)
DUCT FLANGES
DAMPER GRILLE SPEED VIBRATION
MODEL KIT KIT CONTROL HANGER
L2000L D100 G102 72V / 72W V104
L3500EXL D101 G103 75V V104
ACCESSORIES
Produkspesifikasjoner
Merke: | Broan |
Kategori: | Ventilator |
Modell: | L3500EXL |
Trenger du hjelp?
Hvis du trenger hjelp med Broan L3500EXL still et spørsmål nedenfor, og andre brukere vil svare deg
Ventilator Broan Manualer

3 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025
Ventilator Manualer
- Ventilator NewAir
- Ventilator Bosch
- Ventilator BEKO
- Ventilator Exquisit
- Ventilator Café
- Ventilator DeWalt
- Ventilator Philips
- Ventilator Thermex
- Ventilator Hotpoint
- Ventilator Cecotec
- Ventilator Enermax
- Ventilator Comfee
- Ventilator Imarflex
- Ventilator Kogan
- Ventilator Nitecore
- Ventilator Create
- Ventilator Kichler
- Ventilator Midea
- Ventilator BlueBuilt
- Ventilator Orbegozo
- Ventilator NEO Tools
- Ventilator Gemini
- Ventilator Koenic
- Ventilator Panasonic
- Ventilator Lian Li
- Ventilator Westinghouse
- Ventilator Sencor
- Ventilator Canarm
- Ventilator Orava
- Ventilator Mistral
- Ventilator Khind
- Ventilator EMOS
- Ventilator Clean Air Optima
- Ventilator Taurus
- Ventilator Dimplex
- Ventilator Ryobi
- Ventilator Breville
- Ventilator Bimar
- Ventilator Sharkoon
- Ventilator Gamdias
- Ventilator Concept
- Ventilator Livoo
- Ventilator Brandson
- Ventilator CSL
- Ventilator Ausclimate
- Ventilator Nevir
- Ventilator Infiniton
- Ventilator Ufesa
- Ventilator Milwaukee
- Ventilator Scarlett
- Ventilator Daikin
- Ventilator Rowenta
- Ventilator Be Cool
- Ventilator Blaupunkt
- Ventilator Thermaltake
- Ventilator V-Tac
- Ventilator Tristar
- Ventilator Hunter
- Ventilator Ebm-papst
- Ventilator DeepCool
- Ventilator Nedis
- Ventilator Magmatic
- Ventilator Eldom
- Ventilator Elba
- Ventilator Vonroc
- Ventilator Brentwood
- Ventilator ECG
- Ventilator Renkforce
- Ventilator Modern Fan Co.
- Ventilator Quorum International
- Ventilator Bestron
- Ventilator Soler And Palau
- Ventilator Bionaire
- Ventilator Toshiba
- Ventilator S&P
- Ventilator Eurolite
- Ventilator EVOLVEO
- Ventilator Innoliving
- Ventilator Mystery
- Ventilator Middle Atlantic
- Ventilator Duracraft
- Ventilator Mellerware
- Ventilator Home Electric
- Ventilator Tefal
- Ventilator Perfect Aire
- Ventilator Svan
- Ventilator LifeSmart
- Ventilator Signature
- Ventilator Izzy
- Ventilator Lasko
- Ventilator Be Quiet!
- Ventilator Biltema
- Ventilator Emerio
- Ventilator Prime3
- Ventilator KDK
- Ventilator Vornado
- Ventilator Keystone
- Ventilator Savio
- Ventilator InLine
- Ventilator Ardes
- Ventilator Honeywell
- Ventilator Fantini Cosmi
- Ventilator Baxi
- Ventilator Haus & Luft
- Ventilator Ideal
- Ventilator Casablanca
- Ventilator Yamazen
- Ventilator Unold
- Ventilator Aspes
- Ventilator Soler & Palau
- Ventilator Sôlt
- Ventilator Proline
- Ventilator Tornado
- Ventilator Windmill
- Ventilator Premium
- Ventilator ActiveJet
- Ventilator Aerian
- Ventilator Gutfels
- Ventilator Grunkel
- Ventilator Duux
- Ventilator Proficare
- Ventilator Listo
- Ventilator Magnavox
- Ventilator SHE
- Ventilator Air&Me
- Ventilator EWT
- Ventilator Click
- Ventilator Bestherm
- Ventilator ThreeSixty
- Ventilator Valueline
- Ventilator PAX
Nyeste Ventilator Manualer

9 April 2025

9 April 2025

9 April 2025

3 April 2025

2 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025