Danfoss TP5000 Si Bruksanvisning
Les nedenfor 📖 manual på norsk for Danfoss TP5000 Si (2 sider) i kategorien Termostat. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/2
Fig.1
TP5000 Si/TP5000 RF Si
User Instructions
Mon-Fri Sat-Sun
Fig.2
Before programming the thermostat press and release the RESET button to restart
the unit. (Fig. 1)
Setting the Clock and Day
The day and time are set in the factory and therefore it will not normally be necessary
to do this on site. Changes between summer and winter time are handled automatically
by the unit.
Accepting the Factory Pre-settings
The TP5000 Si has pre-set times already programmed in, which often suit most people
(see table below).
Note: If set up for 4 events per day, events 3 & 4 are skipped. If set up for 2 events per
day, events 2, 3, 4 & 5 are skipped and the events are re-numbered.
To adjust the factory pre-settings & set your own time and temperature
programmes
For Days 1-5 (weekdays)
a) Press PROG (Fig. 2) until the 1st pre-set time and temperature (Event 1 Days 1,2,3,4,5)
(Fig. 3).
b) Use + or – buttons (Fig. 4) to adjust the TIME (press and hold to change in 10 min
increments).
c) Use Λ or V buttons (Fig. 5) to adjust the TEMPERATURE.
d) Press PROG (Fig. 2) to move to next preset time & temp (Event 2) (Fig. 6).
e) Repeat steps b, c & d for programming Events 3, 4, 5 & 6.
For Days 6-7 (weekends)
Press •PROG (Fig. 2) to show 1st pre-set time and temperature (Event 1 Days 6-7)
(Fig. 7).
Repeat steps b, c and d above to programme time and temperature events for •
the weekend.
Returning to RUN mode
Press PROG (Fig. 2) – the colon in the LCD display will start to flash (Fig. 8).
Fig.5
Fig.4
Fig.6
Fig.7
Fig.8
Event Time Temp. °C
1 06:30 20
2 08:30 15
3 11:30 20
4 13:30 15
5 16:30 21
6 22:30 15
Event Time Temp. °C
1 07:30 20
2 09:30 20
3 11:30 20
4 13:30 20
5 16:30 20
6 22:30 15
RESET
Fig.3
Complete Shut off - Summer time
Press Λ and V together to enter thermostat mode. A frost protection symbol (snowflake in a
shield) will appear in the display . Press the down arrow ∨ once, OFF will appear in the display.
To return to automatic programming press both ∧ and ∨ together.
Danfoss Randall Ltd
Ampthill Road
Bedford, MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
Fig.10
Fig.11
Selection of time
or actual room
temperature in main
LCD display
Temporary
override of
programmed
temperature
press
together
Frost
Protection
Fig.9
Fig.12
Temporary User Overrides
The TP5000 has several useful overrides which can be selected without affecting the
thermostat programming.
• Selection of time or actual room temperature in main LCD display – press +
and – together to change between settings (Fig. 9).
• Temporary override of programmed temperature – press Λ or V until required
temperature is displayed (override will automatically cancel at beginning of next
programmed event) (Fig. 10).
• Frost Protection – a constant low temperature can be selected whilst away from
home - press Λ and V together (Fig.11). Then use Λ or V to select the required
temperature. To return to automatic programming press Λ and V together again.
Battery Replacement
• Alowbattery symbol will flash in the LCD display (Fig. 12)
You have 15 days to replace the battery before the unit will switch off. •
Remove old batteries and insert new ones. All settings including time are •
maintained.
Press and release the •RESET button to restart the unit. (Fig. 1)
NB. If the display ever goes blank during normal operation, the batteries will need
to be renewed with high quality alkaline cells. The reset button should be pressed
to restart the unit. All times, dates and events will be retained and need not be re-
programmed.
If the property is owned by a landlord he may, for gas safety reasons, have instructed the installer
to set the service interval timer.
If set a visual and audible warning will alert you that the boiler will need servicing within the next
28 days. This warning is repeated each day at noon. (Fig. 15)
If the boiler is not serviced within 28 days the daily audible warning will sound continuously and
can only be cancelled each day by pressing any button on the unit.
In addition, all overrides and programming buttons will be disabled and the heating and hot water
will only operate for 15 minutes in each programmed hour.
As this is a gas safety feature only an installer can reset the service interval timer. This will be done
as part of the boiler service as part of the boiler service.
Service Interval Timer
Fig. 15
Commissioning Instructions
If the thermostat and the receiver have been supplied together in a combined pack, the
units have been paired in the factory and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow steps 1-5 below.
Step 1
TP5000-RF Si - Reset the unit by pressing the recessed reset button.
Step 2
Press and hold V and + buttons (fig. 13) for 3 seconds (TP5000 RF Si now transmits unique signal
continuously for 3 minutes).
Step 3
RX1 - Press and hold buttons PROG and CH1 for 3 seconds until green light flashes once.
(Fig. 14)
Step 4 (Fig.14)
RX2 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 -perform steps 1-2 and then press PROG and CH2 on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 - perform steps 1-2 and then press PROG and CH2 on RX3 then step 5.
Stat 3 - perform steps 1-2 and then press PROG and CH3 on RX3.
Step 5
TP5000Si-RF - Press V or Λ to select temperature - the unit will revert back to operating mode.
IMPORTANT RF Models only
To ensure that the factory programmes are set and the micro-computer is operating correctly
it is essential that you press and hold the RESET button before you begin any commissioning or
programming.
Fig.13
Fig.14
Produkspesifikasjoner
Merke: | Danfoss |
Kategori: | Termostat |
Modell: | TP5000 Si |
Trenger du hjelp?
Hvis du trenger hjelp med Danfoss TP5000 Si still et spørsmål nedenfor, og andre brukere vil svare deg
Termostat Danfoss Manualer
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
Termostat Manualer
- Termostat ORNO
- Termostat Bosch
- Termostat Boneco
- Termostat Siemens
- Termostat EBERLE
- Termostat Schwaiger
- Termostat AEG
- Termostat TP Link
- Termostat Oreg
- Termostat Netatmo
- Termostat Busch-Jaeger
- Termostat Brennenstuhl
- Termostat Somfy
- Termostat Panasonic
- Termostat Schneider
- Termostat EMOS
- Termostat Heatit
- Termostat Dimplex
- Termostat Velleman
- Termostat GE
- Termostat Nexa
- Termostat Nobo
- Termostat Tru Components
- Termostat Bearware
- Termostat Elgato
- Termostat Avidsen
- Termostat STI
- Termostat Hunter
- Termostat Basetech
- Termostat TFA
- Termostat Tesla
- Termostat Renkforce
- Termostat REMKO
- Termostat ATAG
- Termostat Drayton
- Termostat Jung
- Termostat Ambiano
- Termostat Crestron
- Termostat Xavax
- Termostat Techno Line
- Termostat Remeha
- Termostat Heatmiser
- Termostat Wolf
- Termostat GENERAL Life
- Termostat Silvercrest
- Termostat AVM
- Termostat HomePilot
- Termostat Elektrobock
- Termostat Corberó
- Termostat Perel
- Termostat Delta Dore
- Termostat Homematic IP
- Termostat Vimar
- Termostat Emerson
- Termostat Salus
- Termostat Fenix
- Termostat Honeywell
- Termostat Junkers
- Termostat Eliwell
- Termostat Grasslin
- Termostat Jumo
- Termostat Enda
- Termostat Orbis
- Termostat Fantini Cosmi
- Termostat Vemer
- Termostat Qubino
- Termostat Theben
- Termostat EQ3
- Termostat Etherma
- Termostat Saunier Duval
- Termostat Gewiss
- Termostat Viessmann
- Termostat Bticino
- Termostat Conrad
- Termostat Econo-Heat
- Termostat Elro
- Termostat Gira
- Termostat Tado
- Termostat Brink
- Termostat Emmeti
- Termostat Itho
- Termostat Bryant
- Termostat Aube
- Termostat Baxi
- Termostat Seitron
- Termostat Amfra
- Termostat Vaillant
- Termostat Carel
- Termostat Buderus
- Termostat Optima
- Termostat Frico
- Termostat UPM
- Termostat Computherm
- Termostat Veria
- Termostat Innogy
- Termostat Nefit
- Termostat ICY
- Termostat Levica
- Termostat Itho-Daalderop
- Termostat Carrier
- Termostat Radson
- Termostat ChiliTec
- Termostat King
- Termostat ACV
- Termostat Landis Gyr
- Termostat Nest
- Termostat Oventrop
- Termostat IMIT
- Termostat Horstmann
- Termostat ELKO
- Termostat Alecto
- Termostat Google
- Termostat Emko
- Termostat Wachendorff
- Termostat MundoControl
- Termostat Otio
- Termostat Rose LM
- Termostat Tylö
- Termostat Sinustec
- Termostat TrickleStar
- Termostat Finder
- Termostat Sygonix
- Termostat Warmup
- Termostat Plugwise
- Termostat Lowes
- Termostat Go Green
- Termostat Drayton Erie
- Termostat Intertechno
- Termostat EQ-3
- Termostat Johnson Control
- Termostat RWE
- Termostat Webasto
- Termostat Tellur
- Termostat OJ ELECTRONICS
- Termostat Zehnder
- Termostat Plieger
- Termostat HomeMatic
- Termostat Eneco
- Termostat VDH
- Termostat Maico
- Termostat Yokis
- Termostat Eurotronic
- Termostat HQ
- Termostat Ouellet
- Termostat THERMAFLEX
- Termostat Truma
- Termostat Wallair
- Termostat AWB
- Termostat PECO
- Termostat Worcester-Bosch
- Termostat 2Heat
- Termostat EasyTemp
- Termostat Hugo Muller
- Termostat Watts
- Termostat Westfalia
- Termostat Oregon Scientific
- Termostat H-Tronic
- Termostat Z-Wave
- Termostat Easy Timer
- Termostat Fibaro
- Termostat SPC
- Termostat Muller
- Termostat Bulex
- Termostat Helios (Amfra)
- Termostat IR-V
- Termostat Eqiva
- Termostat Hager
- Termostat Energenie
- Termostat Thermy
- Termostat Ferroli
- Termostat Niko
- Termostat Stiebel Eltron
- Termostat De Dietrich
- Termostat POER
- Termostat Technoline
- Termostat Magnum
- Termostat Cotech
- Termostat Hornbach
Nyeste Termostat Manualer
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024