VS-LCD Series Flash
INSTRUCTIONS

2
Thank you for purchasing the Impact VS-LCD Series Studio Strobe. This
light incorporates numerous advanced features, and was designed to
provide many years of trouble-free service. Please read these operating
instructions and safety precautions carefully before operating this
equipment.
Features
• A tactile, “grippy” feel that resists slipping and shock damage
• Cushioned “touch-pad” function control buttons
• Liquid Crystal Display
• Five Stop Range – full power to 1/16th power in .10 f/stop increments
• Red Eye Reduction function
• “Auto Dump” excess power release circuitry
• User-replaceable ash tube
• Commonly available 1/8” mini plug ash sync input
• Universal IEC C13 type computer power cord
• 7˝ grid reector
• Voltage: 100-120V 5 0-6 0Hz
• Built-in optical slave
Power Requirements
This light is designed for use with 110 /120V AC power only, and is supplied with a
3-prong, grounded plug. Do not at tempt to defeat this safety feature. If necessary, use
only grounded extension cords rated for 10 amps or greater.
Warning
There are no user-serviceable parts inside the unit. Only qualied service engineers
should access the inside of the case (Danger – high voltage parts inside). Avoid damage
to both the ash tube and modeling lamp. If the modeling lamp becomes cracked or
damaged in any way, it should be replaced immediately. Do not use your ash unit in an
environment where moisture or ammable vapor is likely to come in contact with the unit.
Turn the power off and unplug the power cord when the unit is not in use. Always remove
the modeling lamp and replace the protective cap when transporting the unit. Avoid
strong light falling onto the slave cell as it will prevent efcient operation. If the strobe
blows a fuse, a replacement fuse can be inserted in the pull-out compartment on the
back of the unit. To ensure long life of the ash capacitors, the ash unit should be
powered up and red several times at least every two months.

3
Contents of carton
Carefully remove the ash unit from the box. You should have the following:
• 110-120V ash unit with protective cap and ash tube installed
• 150W modeling lamp
• 7˝ grid reector • 11´ sync cable
• power cable • user manual
Mount on a stand
Select a stand or support system of suitable weight and dimensions to ensure stable
operation of the unit.
Install Reector & Modeling Lamp
Depress the latch above the protective cap. Rotate the cap counter-clockwise. Pull the
cap off and set aside. Install the modeling lamp by screwing it into the threaded socket.
CAUTION: Do not touch the lamp wi th your bare hands. Oil residue from your ngers can
cause the surface of the lamp to heat unevenly and explode. Use white cotton gloves or a
clean cloth . Install the reector where the protective cap was before. Align the three
pegs on the reector with the three slot s, press the reector in and rotate clockwise
until it locks in place.
Note: Take care when tting or removing reectors or softboxes to not damage the ash
tube assembly. The ash tube is very delicate. Always switch off the unit and disconnect
the power before tting or changing lamps, ash tubes, reectors or softboxes.
Preparing Your Flash for Use
Produkspesifikasjoner
Merke: | Impact |
Kategori: | Lampe |
Modell: | VS-LCD400 |
Trenger du hjelp?
Hvis du trenger hjelp med Impact VS-LCD400 still et spørsmål nedenfor, og andre brukere vil svare deg
Lampe Impact Manualer

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025

13 Januar 2025
Lampe Manualer
- Lampe Ledlenser
- Lampe AFX
- Lampe Hama
- Lampe Neewer
- Lampe Hazet
- Lampe Philips
- Lampe Topeak
- Lampe Schwaiger
- Lampe Godox
- Lampe IKEA
- Lampe Samsung
- Lampe Sony
- Lampe Xiaomi
- Lampe Lutec
- Lampe Golden Lighting
- Lampe ET2
- Lampe Quoizel
- Lampe Crystorama
- Lampe Brennenstuhl
- Lampe NEO Tools
- Lampe Westinghouse
- Lampe Dainolite
- Lampe EMOS
- Lampe Nanlite
- Lampe BeamZ
- Lampe Livoo
- Lampe Steinel
- Lampe Flex
- Lampe Maxim
- Lampe Nordlux
- Lampe Brandson
- Lampe Maginon
- Lampe Ansmann
- Lampe Makita
- Lampe Intermatic
- Lampe V-Tac
- Lampe JBL
- Lampe Nedis
- Lampe Elation
- Lampe Fredrick Ramond
- Lampe Chauvet
- Lampe Karma
- Lampe Ridem
- Lampe Dedra
- Lampe Black Diamond
- Lampe Powerplus
- Lampe Ozito
- Lampe BenQ
- Lampe Hansa
- Lampe Livarno Lux
- Lampe Eurolite
- Lampe Casalux
- Lampe Beghelli
- Lampe American DJ
- Lampe Profoto
- Lampe Petzl
- Lampe Gravity
- Lampe Ikan
- Lampe AVM
- Lampe Olight
- Lampe Vimar
- Lampe Genaray
- Lampe Altman
- Lampe Setti+
- Lampe Kanlux
- Lampe Xline
- Lampe ARRI
- Lampe Osram
- Lampe Zhiyun
- Lampe Honeywell
- Lampe ColorKey
- Lampe Perfect Christmans
- Lampe XCell
- Lampe Physa
- Lampe Jinbei
- Lampe Apa
- Lampe Bolt
- Lampe Heitronic
- Lampe HQ Power
- Lampe Currey & Company
- Lampe Deko-Light
- Lampe Angler
- Lampe Raya
- Lampe Livex Lighting
- Lampe Hinkley Lighting
- Lampe Norwell
- Lampe Ranex
- Lampe COLBOR
- Lampe Lucide
- Lampe Nicols
- Lampe Dorr
- Lampe Pixel
- Lampe Silva
- Lampe Allegri
- Lampe Rotolight
- Lampe SLV
- Lampe Yeelight
Nyeste Lampe Manualer

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025