Side 1/12
60” BLDC
CEILING FAN
CF683DC
Please read this manual carefully before operating this product.
Keep this manual handy for further reference.
IMPORTANT
P/N: 40-12394-06
5
SERIAL NO.:
Safety Precaution Information1
CAUTION
WARNING
1. This appliances is not intended for use by person (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
2.
3. It is recommended to examine the fan suspension system for at least once in every years.
4. Do not attempt to repair fan. Always return fan to our authorised service agent for repair.
5. Safety wire & mounting hook must be able to withstand 10 times the weight of ceiling fan.
(Product net weight: 5.2kg)
6. That the mounting of the suspension system shall be performed by the manufacturer, its
service agent or suitably qualified person.
7. To reduce the risk of injury to person, install fan at least 2.5m(8.3ft) above the ground and
1 meter from the nearest wall.
8. This appliance must be earthed.
9. Do not use any other down rod expect provided by KHIND. This is to ensure good
performance and extra protection.
1. Ceiling Fan must be mounted above 2.5m from the floor and 1m from the wall to the Blade.
Avoid fixing inside the dome ceiling.
2. Ensure Downrod has been fully tigthen to Motor Shaft.
(Bold tightening torque is 800~1000 N.cm)
Can cause injury if ceiling fan drops.
3. R Cotter Pin must fix into Bolt as shown. Can cause injury if
Ceiling Fan drops.
10. The double poles single throw switch must have a contact separation of at least 3mm must
be incorporated in the fixed wiring.
11. Disconnect power supply before dismantling any part for cleaning.
12. For household use only, not intended for any business purposes.
13. Do not use in hot or wet environment or near to flammable materials.
14. The wires in these power supply leads are coloured in accordance with the following
codes. (Green/Yellow-Earth(E), Blue-Neutral(N), Brown-Live(L).
15. If the power supply lead is damaged, it must be replaced by an authorized service agent
or the manufacturer to avoid any hazard.
R Cotter Pin
Ceiling
More than 2.5m More than 1m
WARNING
If unusual oscillating movement is observed, immediately stop using
the fan and contact the manufacturer, its service agent or suitably
qualified persons.
Operating Instruction
1. ON/OFF Button
Press the ON/OFF Button on the remote to start/stop the
fan operation. (Default speed 3 - Forward condition -
Normal Wind).
2. Speed Button
Press the Speed Button (1,2,3,4,5,6) to select desired
speed.
3. Natural Button
Press the Natural Button for fan operate on natural wind.
To back on normal wind, switch off & turn on back the
fan.
4. Forward/Reverse Button
Press the Forward/Reverse Button for fan operate on
forward or reverse rotation.
5. Timer Button
Press Timer Button (1h/4h/8h) to set timer function.
Switch off the fan operation to cancel timer function.
* Battery
The remote control is operated by 2 standard AAA 1.5V
batteries.
1. Pairing Remote Control With Fan Unit.
Pairing code matching mode is used between the Remote Control and Receiver. Turn "ON"
the supply power within 30 seconds and press the ON/OFF button for 5 seconds. It can load
normally after hearing the long sound "bep", which means pairing is successful, and it can
work normally. (Note: Pairing mode is not accepted after turning "ON" the supply power for
30 seconds.)
After installation, it can be used directly. If you want to add or replace a new Remote
Control, you need to pair it again.
2. If the Remote Control unable to remotely control the Receiver:
- Please check whether the switch batteries are in good control. Whether they are fixed
properly and whether they run out of use.
or
- Please check is there any existence of similar remote controlled products nearby, then
check whether they works, because remote controlled product with the same frequency
will disturb each other.
3. Low voltage of battery will affect the sensitivity of the Remote Control and the signal
reception accordingly, must replace if the battery is getting low voltage.
4. Please take out the battery from the Remote Control when leaving unused for long time.
2
Cleaning & Maintenance
Note
1. Keep the fan blade clean & use it at dry place. Do not bend the blades when installing &
maintaining.
2. Wipe away dirt until dry with clean soft cloth, soap & water to clean the fan. Do not use
solvents such as gasoline or petroleum.
ON/OFF Button
Speed Button
Natural Button
Forward/Reverse
Button
Timer Button
Produkspesifikasjoner
Merke: | Khind |
Kategori: | Ventilator |
Modell: | CF683DC |
Trenger du hjelp?
Hvis du trenger hjelp med Khind CF683DC still et spørsmål nedenfor, og andre brukere vil svare deg
Ventilator Khind Manualer
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
Ventilator Manualer
- Ventilator NewAir
- Ventilator Exquisit
- Ventilator DeWalt
- Ventilator Thermex
- Ventilator Cecotec
- Ventilator Comfee
- Ventilator Imarflex
- Ventilator Kogan
- Ventilator Orbegozo
- Ventilator Koenic
- Ventilator Lian Li
- Ventilator Westinghouse
- Ventilator Sencor
- Ventilator Clean Air Optima
- Ventilator Taurus
- Ventilator Ryobi
- Ventilator Gamdias
- Ventilator Brandson
- Ventilator CSL
- Ventilator Ufesa
- Ventilator Milwaukee
- Ventilator Daikin
- Ventilator Be Cool
- Ventilator V-Tac
- Ventilator Tristar
- Ventilator Eldom
- Ventilator Renkforce
- Ventilator S&P
- Ventilator Mystery
- Ventilator Duracraft
- Ventilator Mellerware
- Ventilator Home Electric
- Ventilator Perfect Aire
- Ventilator LifeSmart
- Ventilator Signature
- Ventilator Izzy
- Ventilator Lasko
- Ventilator Prime3
- Ventilator KDK
- Ventilator Vornado
- Ventilator Keystone
- Ventilator Ardes
- Ventilator Honeywell
- Ventilator Baxi
- Ventilator Haus & Luft
- Ventilator Yamazen
Nyeste Ventilator Manualer
28 Oktober 2024
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024