Title Page
1. GENERAL DESCRIPTION.............................................................................. 1
2. PRINCIPLE OF MEASURING ACCUMULATED NOISE EXPOSURE .......... 1
3. INTRODUCTION TO THE DOSE METER ...................................................... 1
4. SPECIFICATION ............................................................................................. 3
5. NOMENCLATURE AND FUNCTIONS............................................................ 6
5-1 The Display and keypad................................................................................6
5-2 The Windscreen and Microphone ................................................................. 7
5-3 The Mounting Clips ....................................................................................... 8
5-4 The Charger .................................................................................................. 9
6. CHARGING THE METER ............................................................................. 10
6-1 Charging...................................................................................................... 10
6-2 Linking Chargers Together .......................................................................... 11
6-3 Battery......................................................................................................... 11
7. GENERAL OPERATION ............................................................................... 12
7-1 Switching on the Meter................................................................................ 12
7-2 Calibrating the Meter................................................................................... 14
7-3 Starting a Measurement Run ...................................................................... 16
7-4 Locking and Unlocking the Keys................................................................. 16
7-5 Stopping a Measurement Run .................................................................... 17
7-6 Pausing a Measurement Run ..................................................................... 17
7-7 Reviewing Measurement Run Data ............................................................ 18
7-8 Switching O the Meter............................................................................... 18
8. CONFIGURING THE METER ....................................................................... 18
8-1 LCD Contrast .............................................................................................. 19
8-2 Date and Time............................................................................................. 19
8-3 Display Timeout ( )............................................................................ 19
8-4 Selecting Dosimeter Setups........................................................................ 20
8-5 Pause Mode ( ) ......................................................................................... 22
8-6 LED Alarms ( ) .................................................................................... 22
8-7 Auto Lock ( )...................................................................................... 23
8-8 Autoscroll ( )......................................................................................... 23
8-9 Timers ( )............................................................................................ 24
8-10 Data Memory Interval Time....................................................................... 26
8-11 Language................................................................................................... 27
8-12 Clear Memory............................................................................................ 27
9. RECALL THE MEMORIZED DATA .............................................................. 28
10. SOFTWARE INSTALLATION AND OPERATION ........................................ 28
-1-
1. GENERAL DESCRIPTION
Thanks for you’re selecting Personal Noise Dose Meter. To ensure that you can get
the most from it we recommend that you read the manual carefully before use.
The personal noise dose meter is test equipment to evaluate the noise condition of
working environment by measuring the accumulated noise exposure. With this test
data, company can ensure the related noise regulation is followed or decide whether
or not to apply certain noise reduction action to avoid the acoustic trauma and
noise-induced hearing loss occurs to the working personnel.
Protected by:
Taiwan: D174456
U.S.A.: D768,514
China: ZL 2015 3 0269895.4
2. PRINCIPLE OF MEASURING ACCUMULATED NOISE EXPOSURE
DOSE is a parameter used to quantify noise exposure measured in a period, during
turns of % noise exposure relative to 90dBA for 8 hours.
i.e. 100% DOSE = 90dBA for 8 hours
This is known as the Criterion. Other criterion are available such as 100% DOSE =
85dBA for 8 hours to meet legislation in dierent countries.
If the person stayed in this environment for 4 hours, he would receive 50%DOSE.
Also if the noise level was say 93dBA, 3dB higher, a 100% DOSE would be
accumulated in only 4 hours, the above example is for a dose meter with 3dB
Exchange Rate, where a 3dB increase in sound level corresponds to a doubling
energy. A dose meter with 5dB Exchange Rate is also, available where the sound
must increase by 5dB to double the dose as required to meet noise legislation in
some countries.
3. INTRODUCTION TO THE DOSE METER
The Noise Dose Meter measure the frequency weighted noise exposures and peak
sound levels simultaneously.
The meter has the following features:
•Multiple simulated dosimeters (termed D1, D2 & D3)
•Simple operation, including direct read-out of results
•Ten built–in standard dose measurement setups:
OSHA-80, OSHA-90, MSHA-80, MSHA-90, DOD, ACGIH, ISO-85, ISO-90, NR-15
and NHO-01
Produkspesifikasjoner
Merke: | PCE Instruments |
Kategori: | Måleutstyr |
Modell: | PCE-MND 10 |
Trenger du hjelp?
Hvis du trenger hjelp med PCE Instruments PCE-MND 10 still et spørsmål nedenfor, og andre brukere vil svare deg
Måleutstyr PCE Instruments Manualer
25 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
Måleutstyr Manualer
- Måleutstyr Fluke
- Måleutstyr Megger
- Måleutstyr Kogan
- Måleutstyr Voltcraft
- Måleutstyr Klein Tools
- Måleutstyr PeakTech
- Måleutstyr Clean Air Optima
- Måleutstyr CSL
- Måleutstyr Kern
- Måleutstyr Einhell
- Måleutstyr Mitsubishi
- Måleutstyr Reely
- Måleutstyr Joy-it
- Måleutstyr Gossen Metrawatt
- Måleutstyr Extech
- Måleutstyr Sonel
- Måleutstyr Flir
- Måleutstyr Testo
- Måleutstyr Ideal
- Måleutstyr Hikmicro
- Måleutstyr Siglent
- Måleutstyr Kopp
- Måleutstyr PICO
- Måleutstyr Wachendorff
- Måleutstyr Ermenrich
- Måleutstyr Beha-Amprobe
- Måleutstyr Adwa
Nyeste Måleutstyr Manualer
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024
26 Oktober 2024