PCE Instruments PCE-VS10 Bruksanvisning
PCE Instruments
Måleutstyr
PCE-VS10
Les nedenfor 📖 manual på norsk for PCE Instruments PCE-VS10 (5 sider) i kategorien Måleutstyr. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/5

Manual
Vibration Meter Sensor Switch
PCE-VS 10
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@industrial-needs.com

Instruction Manual
Vibration Switch VS103&(
Application and Operation
The instrument enables simple and cost efficient monitoring of vibration on rotating machines, for example,
in the frame of preventative maintenance to DIN/ISO 10816. Likewise, it can be used as a limit switch for a
diverse range of processes involving vibration and shock. Thanks to its inbuilt piezoelectric accelerometer
and signal processing, by means of a micro controller, the vibration switch operates reliably and with high
reproducibility.
Selectable filters and integrators, variable alarm settings and the high level of protection IP67 make VS103&(
ideal for a variety of applications, for example:
·Monitoring compressors, pumps, fans, generators
·Rail vehicles
·Quality control
·Transporting fragile goods
·Surveillance of doors and gates
·Impact and drop testing
By means of the inbuilt piezoelectric accelerometer, VS10 monitors vibrations perpendicular to the lid of its3&(
casing. It measures both positive and negative excitation.
3&(VS10 has a digital signal processor and a relay output for signalization. It indicates alarm status via green
and red LED's.
Parametrization
The parametrization is carried out with PC software via a common micro
USB cable. To connect the USB cable, unscrew the four socket head screws
and remove the lid. Inside you will see the USB connector (Figure 1).
Caution: If a USB cable is connected, the power will be supplied by the PC.
Make sure the power is never supplied via a USB cable and the connection
terminals simultaneously.
When connecting VS10 to a PC for the first time, you will be prompted 3&(
install the driver. The driver file “MMF_VCP.zip” can be found on our
website:
Unzip and save both the enclosed files to a directory on the computer.
When Windows requests the location of the instrument driver, enter this di-
rectory. The instrument driver is signed and runs with Windows XP, Vista, 7, 8 and 10.
The driver installs a virtual COM Port on the PC and operates in CDC mode, thus enabling simple control
via the ASCII commands.
To setup the VS10 the PC-Software is available under the above link. Unzip the file vs1x.zip into a di-3&( VS1x
rectory on your PC and then start . The installation directories can be changed if needed. The pro-setup.exe
gram is a LabView application and for this reason installs several components of the LabView Run-Time en -
vironment from National Instruments.
Once installed, the program is located under in the start menu of your computer. (Figure 2).Metra Radebeul
Figure 1: Connections

To establish a connection to VS10, press . The program searches COM-Ports 1 to 50 for the in-3&( Search VS1x
strument. As soon as it has been found the status report appears and the instrument settingsVS1x connected
are read.
In the row next to the COM port number you will find the non-editable data, model, version, serial number
and date of calibration. You can enter the device name yourself.
When entering the gain, this refers to the analogue pre-amplification before the analogue-to-digital converter
stage. The gain levels 1, 10 and 100-fold are available for selection as well as automatic gain switching. In
many cases automatic gain setting is most appropriate. It can, however, occasionally be disadvantageous if
single shock pulses are measured. If previously only low amplitudes had been recorded, it may occur that
short single impulses fail to trigger the alarm signal immediately, due to the switching of the gain. In such
cases a fixed gain should be set according to the maximum expected amplitude ( ). fix
Under there is a row of high and low pass filter combinations to choose from. DependingFilter / Integrator
on the area of application, you can monitor either acceleration without integration ( .) or the single inte-accel
grated signal of velocity ( .). For vibrations below 1 kHz, for which the resulting energy is of relevance,veloc
it is recommendable to monitor velocity, whereas for measurements involving higher frequencies and im -
pacts, acceleration is usually preferred.
Under Warning/Alarm RMS you can find the limit value settings. Here your can select whether values or
Peak values are to be monitored. Monitoring peak values can be advantageous for recording single events,
while RMS is relevant for trend monitoring, for example, in the field of machine condition monitoring. The
Alarm limit is entered in the unit of measurement (m/s² or mm/s). The instrument can give a warning signal
before it reaches the alarm limit. The warning threshold is entered as a percentage of the alarm limit.
Figure 2: Parameter Program
Produkspesifikasjoner
Merke: | PCE Instruments |
Kategori: | Måleutstyr |
Modell: | PCE-VS10 |
Trenger du hjelp?
Hvis du trenger hjelp med PCE Instruments PCE-VS10 still et spørsmål nedenfor, og andre brukere vil svare deg
Måleutstyr PCE Instruments Manualer

27 Mars 2025

27 Mars 2025

14 Mars 2025

14 Mars 2025

14 Mars 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025
Måleutstyr Manualer
- Måleutstyr ORNO
- Måleutstyr Hazet
- Måleutstyr Fluke
- Måleutstyr IFM
- Måleutstyr Megger
- Måleutstyr Kogan
- Måleutstyr Festo
- Måleutstyr Voltcraft
- Måleutstyr Panasonic
- Måleutstyr Klein Tools
- Måleutstyr PeakTech
- Måleutstyr Clean Air Optima
- Måleutstyr Flex
- Måleutstyr Chauvin Arnoux
- Måleutstyr CSL
- Måleutstyr Milwaukee
- Måleutstyr Kern
- Måleutstyr Ansmann
- Måleutstyr Einhell
- Måleutstyr Mitsubishi
- Måleutstyr PCE
- Måleutstyr Megasat
- Måleutstyr Reely
- Måleutstyr Joy-it
- Måleutstyr Basetech
- Måleutstyr Gossen Metrawatt
- Måleutstyr TFA
- Måleutstyr Sauter
- Måleutstyr Owon
- Måleutstyr Extech
- Måleutstyr Techno Line
- Måleutstyr Murideo
- Måleutstyr Stabila
- Måleutstyr Uni-T
- Måleutstyr Sonel
- Måleutstyr Flir
- Måleutstyr Testo
- Måleutstyr Enda
- Måleutstyr Vemer
- Måleutstyr Ideal
- Måleutstyr Steinberg
- Måleutstyr Hikmicro
- Måleutstyr Siglent
- Måleutstyr Kopp
- Måleutstyr PICO
- Måleutstyr Wachendorff
- Måleutstyr Ermenrich
- Måleutstyr Beha-Amprobe
- Måleutstyr Adwa
- Måleutstyr Tempo
- Måleutstyr Burg-Wachter
- Måleutstyr Metrix
- Måleutstyr Technics
- Måleutstyr Brookhuis
- Måleutstyr Toolland
- Måleutstyr Angler
- Måleutstyr Ebro
- Måleutstyr Testboy
- Måleutstyr Senseca
- Måleutstyr Crowcon
- Måleutstyr Aeroqual
- Måleutstyr DriveTest
- Måleutstyr PQ Plus
- Måleutstyr Intact
- Måleutstyr Kyoritsu
- Måleutstyr Helvi
- Måleutstyr Aerospace Logic
- Måleutstyr MGL Avionics
- Måleutstyr Dostmann Electronic
- Måleutstyr Kübler
- Måleutstyr HT Instruments
- Måleutstyr Rotronic
- Måleutstyr CEM
- Måleutstyr Jonard Tools
- Måleutstyr Phoenix Contact
- Måleutstyr Victron Energy
- Måleutstyr Testec
- Måleutstyr Eastron
- Måleutstyr GW Instek
- Måleutstyr Camille Bauer
- Måleutstyr Duro Pro
- Måleutstyr BAXTER
- Måleutstyr Mitutoyo
Nyeste Måleutstyr Manualer

27 Mars 2025

27 Mars 2025

27 Mars 2025

27 Mars 2025

27 Mars 2025

26 Mars 2025

26 Mars 2025

22 Mars 2025

18 Mars 2025

11 Mars 2025