PCE Instruments PCE-W3 Bruksanvisning
PCE Instruments
Måleutstyr
PCE-W3
Les nedenfor 📖 manual på norsk for PCE Instruments PCE-W3 (3 sider) i kategorien Måleutstyr. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/3

PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
MANUAL
Moisture Analyser
PCE-W3

1. Application
Moisture Meter for Waste Paper is designed to rapidly det ermine the level of moisture contents of waste paper.
2. Operation principle
Moisture meter measures the resistance of the m ate rial (waste paper). It has b een calibrated for normal
composition of waste paper.
3. Technical data
Range 6% - 30%
Power 9V, 1 battery 6F22
Electrode length 85 mm
Size 80 * 180 * 250 mm
Limitations
This warranty becomes null and void if you fail to pack your PCE-W3 in a manner consistent with the original
product packaging and dam-age occurs during pr uct shipment. This warranty does not cover: circumstance od
beyond our company’s control; service r equired as the result of unauthorized modiÿcations or service; misuse,
abuse; failure to follow our com pany operating or main tenance instructions. Repai r or replacement without
charge is our company’s only obligat ion under thi s warranty. Our comp any will not be res ponsible for any
special, consequential or incidental damages resulting fr om the purchase, use, or im proper functioning of this
equipment regardless of the cause. Such damages for which our company’s will not be responsible include, but
are not limited to, loss of revenue or proÿt, downtime cost s, loss of use of the equipment, cost of any substitute
equipment, facilities of services, or claims of your customers for such damages.
GUA N RA TEE
The manufacturer guarantees the correct functioning of the Moisture Meter for Waste Paper PCE-W3 under
normal use for a period of 12 months.
NOTE: "This instrument doesn’t have ATEX protection, so it should not be used in potentially explosive
atmospheres (powder, ˜ammable gases)."

4. Measurements
Conduct the measurements of moisture contents of waste paper following these steps:
• take the device out of its case and remove the protective cap,
• connect the device with the electrode using the wire provided,
• turn the power on,
• slide the electrode into the waste paper (if it’s compressed) or firmly press the electrode against
a single piece of waste paper,
• read the result,
• repeat the measurement with at least 3 randomly selected samples,
• the final result is an average of all the measurements,
• turn the power off.
WARNING:
The measuring range of the device is 6% - 30%. Moisture contents below 6% is indicated as „LO”.
Results over 30% should be considered as rough estimates.
5. Changing the battery and storage
The device is equipped with a power level control circuit. When the power drops below acceptable level a sign ”LO BAT”
appears on the left side of the LCD. This indicates that the battery has expired and should be replaced with a new one.
To replace the battery unscrew the screw on the back of the instrument and carefully remove the back panel. Store the
device in a dry place.
NOTE: "This instrument doesn t ha’ ve ATEX protection, so it should not be used in potentially explosi e v
atmosp
Produkspesifikasjoner
Merke: | PCE Instruments |
Kategori: | Måleutstyr |
Modell: | PCE-W3 |
Trenger du hjelp?
Hvis du trenger hjelp med PCE Instruments PCE-W3 still et spørsmål nedenfor, og andre brukere vil svare deg
Måleutstyr PCE Instruments Manualer

27 Mars 2025

27 Mars 2025

14 Mars 2025

14 Mars 2025

14 Mars 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025

26 Februar 2025
Måleutstyr Manualer
- Måleutstyr ORNO
- Måleutstyr Hazet
- Måleutstyr Fluke
- Måleutstyr IFM
- Måleutstyr Megger
- Måleutstyr Kogan
- Måleutstyr Festo
- Måleutstyr Voltcraft
- Måleutstyr Panasonic
- Måleutstyr Klein Tools
- Måleutstyr PeakTech
- Måleutstyr Clean Air Optima
- Måleutstyr Flex
- Måleutstyr Chauvin Arnoux
- Måleutstyr CSL
- Måleutstyr Milwaukee
- Måleutstyr Kern
- Måleutstyr Ansmann
- Måleutstyr Einhell
- Måleutstyr Mitsubishi
- Måleutstyr PCE
- Måleutstyr Megasat
- Måleutstyr Reely
- Måleutstyr Joy-it
- Måleutstyr Basetech
- Måleutstyr Gossen Metrawatt
- Måleutstyr TFA
- Måleutstyr Sauter
- Måleutstyr Owon
- Måleutstyr Extech
- Måleutstyr Techno Line
- Måleutstyr Murideo
- Måleutstyr Stabila
- Måleutstyr Uni-T
- Måleutstyr Sonel
- Måleutstyr Flir
- Måleutstyr Testo
- Måleutstyr Enda
- Måleutstyr Vemer
- Måleutstyr Ideal
- Måleutstyr Steinberg
- Måleutstyr Hikmicro
- Måleutstyr Siglent
- Måleutstyr Kopp
- Måleutstyr PICO
- Måleutstyr Wachendorff
- Måleutstyr Ermenrich
- Måleutstyr Beha-Amprobe
- Måleutstyr Adwa
- Måleutstyr Tempo
- Måleutstyr Burg-Wachter
- Måleutstyr Metrix
- Måleutstyr Technics
- Måleutstyr Brookhuis
- Måleutstyr Toolland
- Måleutstyr Angler
- Måleutstyr Ebro
- Måleutstyr Testboy
- Måleutstyr Senseca
- Måleutstyr Crowcon
- Måleutstyr Aeroqual
- Måleutstyr DriveTest
- Måleutstyr PQ Plus
- Måleutstyr Intact
- Måleutstyr Kyoritsu
- Måleutstyr Helvi
- Måleutstyr Aerospace Logic
- Måleutstyr MGL Avionics
- Måleutstyr Dostmann Electronic
- Måleutstyr Kübler
- Måleutstyr HT Instruments
- Måleutstyr Rotronic
- Måleutstyr CEM
- Måleutstyr Jonard Tools
- Måleutstyr Phoenix Contact
- Måleutstyr Victron Energy
- Måleutstyr Testec
- Måleutstyr Eastron
- Måleutstyr GW Instek
- Måleutstyr Camille Bauer
- Måleutstyr Duro Pro
- Måleutstyr BAXTER
- Måleutstyr Mitutoyo
Nyeste Måleutstyr Manualer

27 Mars 2025

27 Mars 2025

27 Mars 2025

27 Mars 2025

27 Mars 2025

26 Mars 2025

26 Mars 2025

22 Mars 2025

18 Mars 2025

11 Mars 2025