Perlick BC48RT-BS-STK Bruksanvisning
Perlick
Vinklimaskap
BC48RT-BS-STK
Les nedenfor 📖 manual på norsk for Perlick BC48RT-BS-STK (12 sider) i kategorien Vinklimaskap. Denne guiden var nyttig for 4 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/12
Form No. Z2295
Rev. 04.20.23
BC72 shown
C
US
MODELS
BC24
BC36
BC48
BC60
BC72
BC96
INSTALLATION AND OPERATION INSTRUCTIONS
FLAT TOP BOTTLE COOLER - BC SERIES
Warranty
To register your product, visit our web site at www.
perlick.com. Click on “Commercial”, then “Service”.
Click on the link “Warranty Registration Form”. You
must complete and submit this form or the installation
date will revert back to the ship date.
Please record the purchase date and the dealer’s name,
address and telephone number below.
Model Number: ____________________________
Serial Number: _____________________________
Purchase Date: ____________________________
Dealer Name & Address _____________________
_________________________________________
_________________________________________
_________________________________________
Phone Number ____________________________
Introduction
Congratulations on your purchase of a Perlick
commercial underbar product. This manual has been
prepared to assist you in the installation of your cabinet
and to acquaint you with its operation and maintenance.
This manual has been prepared to assist you in the
installation of your under counter refrigerator and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualied service agents. For
your own protection, never return merchandise for credit
without our approval.
We thank you for selecting a Perlick product and assure
you of our continuing interest in your satisfaction.
GENERAL INFORMATION
The Perlick Corporaon veries this product does not contain a prohibited refrigerant as dened by the California Air Resource Board (CARB), the state of
New York, and any other state with HFC prohibion laws. This product does not contain HFC’s. The following disclosure statement is provided to comply with
the CARB regulaon:
This equipment is prohibited from use in California with any refrigerants on the “List Of Prohibited Substances” for that specic end use, in accordance with
the California Code of Regulaons, tle 17, secon 95374. This disclosure statement has been reviewed and approved by the Perlick Corporaon and the
Perlick Corporaon aests under penalty of perjury, that these statements are true and accurate.
FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
2
TABLE OF CONTENTS
IMPORTANT!
Read and understand all information in this manual before attempting the installation.
All plumbing and electrical work must be performed by a qualied technician and
conform to all applicable state and local codes.
General Information 1 ................................................................................................................................................................................
Safety 2 ............................................................................................................................................................................................................
Cabinet Specications 3 ............................................................................................................................................................................
Cabinet Drawings 4 .....................................................................................................................................................................................
Preparing the Cabinet for Use
Refrigerant ...........................................................................................................................................................................................5
Uncrating and Inspection 5 ..............................................................................................................................................................
Installation ...........................................................................................................................................................................................5
Electrical ...............................................................................................................................................................................................5
Use and Operation 6 ...................................................................................................................................................................................
Repair & Maintenance 6 ............................................................................................................................................................................
Installing Casters or Legs 6 .......................................................................................................................................................................
Placing the Cabinet 6 .................................................................................................................................................................................
Adjustable Partitions and Shelving 6 ...................................................................................................................................................
Placing the Cabinet 6 .................................................................................................................................................................................
Digital Temperature Control .................................................................................................................................................................7
Maintenance 7 ..............................................................................................................................................................................................
Cleaning the Condenser 7 .................................................................................................................................................................
Cleaning the Doors 7 ..........................................................................................................................................................................
Cleaning the Cabinets 7 .....................................................................................................................................................................
Wiring Diagrams 8 .......................................................................................................................................................................................
Replacement Parts 10 ................................................................................................................................................................................
SAFETY
PLEASE READ all instructions completely before attempting
to install or operate the unit. Take particular note of the
DANGER, WARNING and CAUTION information in the
manual. The information is important for the safe and
ecient installation, operation and care of your Perlick unit.
DANGER
Indicates a hazard that WILL result
in serious injury or death if
precautions are not followed.
W GARNIN
Indicates a hazard MAY cause
se rio u s in ju ry or de at h if
precautions are not followed.
CAU NTIO
Indicates a hazard where minor
or moderate injury may occur if
precautions are not followed.
N EOTIC
Indicates that property damage
m a y o c c u r i f wa r ni ng s o r
instructions are not followed.
WARNING: California Prop 65 Noce
These products may expose you to chemicals including Chromium, which are known to the state of California to cause cancer and birth
defects or other reproducve harm. For more informaon on whether a product in this list contains these chemicals, please refer to the
specic product page at . Or to nd out more about Prop 65, go to perlick.com P65Warnings.ca.gov.
FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3Form No. Z2295
Rev. 04.20.23
JOB
AREA
ITEM NO.
MODEL NO.
BC24 SERIES
BC36 SERIES
BC48 SERIES
BC60 SERIES
BC72 SERIES
BC96 SERIES
C
US
BC72 shown
BC24 shown
R290
Refrigerant
MODEL NUMBERS BC24 BC36 BC48 BC60 BC72 BC96
EXTERIOR CABINET
DIMENSIONS
Length - in. (mm) 24 (610) 36 (914) 48 (1219) 60 (1524) 72 (1829) 96 (2436)
Depth - in. (mm) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610)
Height - in. (mm) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866)
INTERNAL NET VOLUME - cubic ft. (liters) 4.2 (118) 8.6 (242) 12.5 (353) 16.3 (462) 20.3 (575) 28.3 (800)
CASE CAPACITY (12 bottles) 5.5 9.8 17.2 21.0 28.3 41.0
CASE CAPACITY (12 cans) 7 16 25 30 36 58
SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235)
CABINET CONSTRUCTION (INTERIOR) All models have stainless steel walls and oor.
CABINET CONSTRUCTION (EXTERIOR)
Choice of black, stainless steel and all stainless.
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized.
Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized.
All Stainless Option: Front, ends, back and bottom are all stainless steel.
DOORS AND HARDWARE Sliding style open with standard locks. Stainless steel top and bottom pans. Die cast handle
PLUMBING No drain required. Condensate evaporates automatically.
INSULATION 2 inch foamed-in-place, environmentally friendly Ecomate® polyurethane insulation. Blowing agent R-611.
VENTILATION 2’ model is front vented, all other models require 2” clearance from wall on either left end or back of cabinet for proper
air ow.
TEMPERATURE
SPECIFICATIONS
Default Temperature Setpoint:
Standard Temp (RT) Models - °F [°C] 38 [3.3]
Adjustable Setpoint Range:
Standard Temp (RT) Models - °F [°C] 34 - 40 [1.1 - 4.4]
Default Temperature Setpoint:
Low Temp (LT) Models - °F [°C] 30 [-1.1]
Adjustable Setpoint Range:
Low Temp (LT) Models - °F [°C] 28 - 34 [-2.2 - 1.1]
Default Temperature Setpoint:
Wine Temp (WT) Models - °F [°C] 50 [10.0]
Adjustable Setpoint Range:
Wine Temp (WT) Models - °F [°C] 45 - 60 [7.2 - 15.6]
ELECTRICAL
SPECIFICATIONS
Supply 120 VAC/60 Hz/1 Ph
Running Load Amps 1.9 1.9 3.1 4.4 4.4 4.4
Power Cord 6-foot length with NEMA 5-15 plug.
Thermostat NSF Listed electronic control.
Defrost Type Automatic electric defrost (Low Temp models only).
Lighting Type LED (136 Lumens, 5500K)
REFRIGERATION
SPECIFICATIONS
Condensing Unit Hermetic condensing unit pulls out for service and cleaning.
Expansion Device Capillary Tube
Refrigerant R290
Refrigerant Charge (g) 90 110 120 120 120 120
Compressor H.P. 1/6 1/6 1/5 1/4 1/4 1/4
Total Heat of Rejection
At 75°F ambient (BTU/h) 1420 1420 1920 2980 2980 2980
OPTIONAL ACCESSORIES Floor racks • Casters • Bottle opener and receiver • Bin dividers
Speed rails • Adjustable legs • Roller basket shelving
*
Produkspesifikasjoner
Merke: | Perlick |
Kategori: | Vinklimaskap |
Modell: | BC48RT-BS-STK |
Trenger du hjelp?
Hvis du trenger hjelp med Perlick BC48RT-BS-STK still et spørsmål nedenfor, og andre brukere vil svare deg
Vinklimaskap Perlick Manualer
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
Vinklimaskap Manualer
- Vinklimaskap Hisense
- Vinklimaskap Smeg
- Vinklimaskap Russell Hobbs
- Vinklimaskap Edgestar
- Vinklimaskap Kogan
- Vinklimaskap Summit
- Vinklimaskap Kluge
- Vinklimaskap Vintec
- Vinklimaskap Witt
- Vinklimaskap Landmark
- Vinklimaskap Fhiaba
- Vinklimaskap Avallon
Nyeste Vinklimaskap Manualer
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024