FILTRATION SYSTEM INSTALLATION INSTRUCTIONS
ITEM FL1000
www.btiaquasolutions.com
REV / /1811 19
Remove mounting-bracket from
Filtration System Head. Select “Snap
Fit” (two outside screws) or “Rotary”
(one center screw) bracket mounting.
The “Rotary” bracket mounting should
be used if varying positions of
Filtration System is required in cabinet.
SPECIFICATIONS
• NSF/ANSI 42 & 53 CERTIFIED
• 0.5 MICRON CARBON-BLOCK FILTER
• .55 US GAL/2.1L GPM FLOW RATE
• 1500 US GAL/5,678 L CAPACITY
• 3-STAGE FILTER
• 3” x 11” SPACE SAVING DESIGN
• BUILT-IN PRV
• SQC HEAD
• ECO-FRIENDLY, RECYCLABLE
TOOLS REQUIRED:
PENCIL, SCREWDRIVER
TO VIEW INSTALLATION VIDEO VISIT
www.btiaquasolutions.com
1 2
Measure and mark screw hole(s) for
your desired lter location.
Make sure “Location-Lug” on bracket
is on top.
3
A
Position Filtration System with label and
black location arrow facing you.
Push the lter head into bracket until you
feel it click into place.
It will only t one way, with label and
black location arrow facing you.
4Push one end of tubing (F) into angle shut-
off valve (D). Push other end of tubing into
“L-Fitting”, pre-installed in the “inlet” on top
of lter.
Push one end of tubing (F) into “outlet”
connector on top of lter. Connect other end
of tubing to faucet-stem of ltration faucet.
If using a BTI Filtration Faucet, all items for
connection are supplied with faucet.
To remove a tube, push down on the collet
while pulling on the tube.
Turn on the water supply and check for
leaks. Flush at least one gallon of water
through the system before use. Write the
installation and lter change dates on the
label for future reference.
Location-Lug
NOTE: If using with a BTI
Hot/Cold Filtration Faucet, skip to Step 5.
Install angle shut-off valve (D) supplied with
BTI Filtration System.
Shut-off cold-water supply (E). Disconnect
line/hose (C) to kitchen faucet from cold-water
supply shut-off valve (E).
Connect angle shut-off valve (D) to cold-water
supply shut-off valve (E). Connect line/hose
from kitchen faucet (C) to angle shut-off valve
(D).
Cut the 1/4” O.D. inlet/outlet tubing (supplied)
to the correct lengths, ensuring the cut ends
are square and clean.
(A) FILTRATION FAUCET
(B) BTI FILTRATION SYSTEM
(C) LINE/HOSE TO KITCHEN FAUCET
(D) ANGLE SHUT-OFF VALVE (supplied)
(E) COLD-WATER SUPPLY SHUT-OFF VALVE
(F) 1/4” O.D. TUBING (supplied)
B
C
D
E
F
F
FILTRATION SYSTEM INSTALLATION WITH COLD ONLY FILTRATION FAUCET

FILTRATION SYSTEM INSTALLATION INSTRUCTIONS, continued
ITEM FL1000
www.btiaquasolutions.com
REV / /1811 19
A
5Connect 3/8” Female Side of adapter (G)-
(supplied) to braided blue label
cold-water in hose. Push one end of tubing
(F) into 1/4” Push-Fit Side of adapter (G).
Push other end of tubing (F) into “outlet”
connector on top of filter.
To remove a tube, push down on the collet
while pulling on the tube.
Turn on the water supply and check for
leaks. Flush at least one gallon of water
through the system before use.
Write the installation and filter change dates
on the label for future reference.
Install angle shut-off valve (D) supplied with
BTI Filtration System.
Shut-off cold-water supply (E). Disconnect
line/hose (C) to kitchen faucet from cold-water
supply shut-off valve (E).
Connect angle shut-off valve (D) to cold-water
supply shut-off valve (E). Connect line/hose
from kitchen faucet (C) to angle shut-off valve
(D).
Cut the 1/4” O.D. inlet/outlet tubing (supplied)
to the correct lengths, ensuring the cut ends
are square and clean.
Push one end of tubing (F) into angle shut-
off valve (D). Push other end of tubing into
“L-Fitting”, pre-installed in the “inlet” on top
of lter.
(A) FILTRATION FAUCET
(B) BTI FILTRATION SYSTEM
(C) LINE/HOSE TO KITCHEN FAUCET
(D) ANGLE SHUT-OFF VALVE (supplied)
(E) COLD-WATER SUPPLY SHUT-OFF VALVE
(F) 1/4” O.D. TUBING (supplied)
(G) w/faucet3/8” / 1/4” ADAPTER (supplied )
B
C
D
E
F
F
FILTRATION SYSTEM INSTALLATION W BTI HOT/COLD FILTRATION FAUCET/ AQUA-SOLUTIONS
ITEMS: HC2100, HC2200, HC2400
G
Produkspesifikasjoner
Merke: | BTI Aqua-Solutions |
Kategori: | Vannfilter |
Modell: | FLC1000 |
Trenger du hjelp?
Hvis du trenger hjelp med BTI Aqua-Solutions FLC1000 still et spørsmål nedenfor, og andre brukere vil svare deg
Vannfilter BTI Aqua-Solutions Manualer

1 April 2025

1 April 2025
Vannfilter Manualer
- Vannfilter Laica
- Vannfilter Haier
- Vannfilter Philips
- Vannfilter Panasonic
- Vannfilter Fluval
- Vannfilter GE
- Vannfilter Eden
- Vannfilter JBL
- Vannfilter Eldom
- Vannfilter Aquael
- Vannfilter Waterdrop
- Vannfilter Stiebel Eltron
- Vannfilter Astralpool
- Vannfilter JANDY
- Vannfilter Platypus
- Vannfilter Heissner
- Vannfilter Puretec
- Vannfilter LARQ
Nyeste Vannfilter Manualer

29 Mars 2025

27 Februar 2025

21 Februar 2025

6 Januar 2025

1 Januar 2025

31 Desember 2025

28 Desember 2024

27 Desember 2024

27 Desember 2024

25 Desember 2024