Product Category
ECM S10 Partition Sensor • Setup Guide
ECM S10 is a pollution degree 2 product with a rated impulse voltage of 330 V. Construction of Control is dened as
“Independently Mounted”. The purpose of the control is considered as an “Operating Control” with Type 1 Action.
The Extron ECM S10 is an eBUS
® compatible partition sensor. The sensor consists of a transmitter and receiver pair, which are
mounted, face down, in the ceiling on either side of a moveable room partition. The receiver is mounted up to 10 feet (3 m) away
from the transmitter and in direct line of sight. When the partition is open, the receiver detects the IR signal from the transmitter.
When the partition is closed, the IR signal from the transmitter is blocked and the receiver can no longer detect a signal.
The control signal indicating whether the partition is open or closed can be sent through the eBUS port. Alternatively, it can be
sent through the digital output port, which allows communication with Extron IPCP control processors, Extron legacy control
products, or third-party controllers that have digital I/O ports.
Multiple ECM S10 partition sensors can be connected to a single control processor. If the control signal is sent via eBUS, up to
eight partition sensors can be connected to the IPCP control processor.
NOTE: Extron IPCP control processors are the only control processors that have an eBUS port.
If the control signal is sent via the digital port, the number of partition sensors is limited only by the number of digital I/O ports
available on an Extron or third-party control processor.
The receiver is powered through the eBUS port. The transmitter is powered by a 14 VDC cable connected to the receiver. The
transmitter does not have an eBUS port.
A (2)Decorator Style Faceplate Cover Mounting Location
Used to attach the oversized 1-gang decorator style cover.
B (2) — Used to mount the device US 1-gang Mounting Slots
to any standard US 1-gang junction box. The slots allow minor
alignment adjustments.
C (2) — Used to mount the EU and MK 1-gang Mounting Slots
device to any standard EU or MK 1-gang junction box. The
slots allow minor alignment adjustments.
D Transmitter Power Input — A 12-inch (305 mm) pigtail,
terminated with a two-pole captive screw connector accepts
power from the receiver power output (see G, below). A
separate cable, connecting the pigtail to the receiver, must be
provided by the user.
E — The ECM S10 receiver has yellow, red, eBUS Status LEDs
and green LEDs that provide diagnostic information about
the connection, communication, and power status of the
panels. For more information about how the LEDs are used for
troubleshooting see Step 5 — Testing and Troubleshooting
the System on page 12.
F — This four-pole captive screw connector provides power to the ECM S10 receiver and can also provide eBUS Port
communication between the ECM S10 and an Extron IPCP control processor.
NOTES:
If the control signal is sent to the control processor by eBUS, cables are connected to all four poles (see Step 2
Connecting Cables to the Units on page 6).
If the control signal is sent to the control processor by digital output port, cables are connected to the +V and G
poles only (see ).Step 2 — Connecting Cables to the Units
G — This two-pole captive screw connector provides 14 VDC to the transmitter.Receiver Power Output
H — If the control signal is sent to the control processor by digital output, connect this two-pole captive Digital Output Port
screw connector to a Digital I/O port on a control processor.
Panel Features
Rear Panel
STATUS
eBUS +V OUT D OUT
LINK ERROR
COM
ERROR
ID
PWR LOAD = 1.0 W
+V +S -S G 14 G GOUT
w
ECM S10 Receiver
EC
M S10 rTransmitte
A
B
C
B
A
C
E
F
G
H
D
Figure 1. Rear Panel Features of ECM S10
Transmitter (left) and Receiver (right)
2
ECM S10 Partition Sensor • Setup Guide (Continued)
Front Panel
w
RX
K
NO R T H
AMERICA
e
w
TX
K
NO R T H
AMERICA
e
C
B
A
D
1
2
3
w
RESET
BUS ID
RX
1
M
S
B
L
S
B
EU / MK
NO RT H
AMERICA
H
G
D L
MIN MAX
E
F
Figure 2. Front Panel Features of ECM S10
A — The transmitter emits an IR signal through this slot in the cover.IR Signal Source
B — The receiver detects the IR signal from the transmitter, when it passes through this slot in the cover.IR Signal Detector
C — The transmitter has one red LED. The receiver has one amber and one green LED. These provide Sensor Status LEDs
feedback about the power and alignment status:
Sensor Set to Normally Open (D)
Digital OutputTransmitter LED Receiver LEDs
Red LED Amber LED Green LED
Sensors aligned and
partition open ON OFF ON Open/Logic High
Partition closed ON ON ON Closed/Logic Low/
Ground
Sensors not aligned
and partition open ON ON ON Closed/Logic Low/
Ground
If the red transmitter LED is off, the transmitter is not receiving power.
If the green receiver sensor LED is off, the receiver is not receiving power.
D — Both the transmitter and receiver have sensor covers. They are removed by gently pressing the Removable Sensor Cover
sides of the sensor cover to free the catches on both sides from the slots in the metal mounting plate. The cover can then be
pulled straight out.
Removing the cover from the receiver provides access to the BUS ID DIP switches, the sensitivity adjustment control, the
sensor setting control, and button.
E — By default, the sensitivity of the detector in the receiver is set to maximum. Extron recommends Sensitivity adjustment
that it remains at this setting.
F — By default, this is set to (normally open). If required, use a small, at-bladed screwdriver to turn the Sensor Setting
setting to (normally closed).
G — Up to eight partition sensors congured for eBUS operation can be connected to one control BUS ID DIP Switches
processor. Each eBUS device connected to the same control processor must have a unique BUS ID, which is set using the
DIP switches (see on page 9).
Step 3 — Setting the BUS ID Addresses
H — If required, press this recessed button to reset the rmware to the factory installed version.Reset Button
To reset the firmware
1. Disconnect the eBUS cable that is providing power.
2. Press and hold down the button and, while holding down the button, reconnect eBUS cable.
3. Release the button 1 second after reconnecting power. When the eBUS Connection Status LED lights, the reset
process is complete.
If the reset is carried out while the ECM S10 is sending the partition status signal via I/O ports (no control signal via eBUS),
the rmware is reset to the factory default. However, if the reset is carried out while the partition status signal is sent via
eBUS, the rmware is initially reset to the factory default but the IPCP control processor may then push a more recent version
of the rmware to the ECM S10.
1Transmitter with sensor cover
2Receiver with sensor cover
3Receiver with cover removed.
3
Product Category
Installing the ECM S10 Partition Sensor
The ECM S10 can transmit information about the partition status (open or closed) in any of the following ways:
Via eBUS port to an Extron control processor
Via digital output port to an Extron control processor
Via digital output port to a third-party control processor
Installation Overview
How the partition status signal is sent to the control processor determines how the ECM S10 receiver is connected to the control
processor. This, in turn, affects how the sensor is installed. The following sections describe:
Before You Start (see page 3)
Downloading Software (see page 3)
Considerations for Placing the ECM S10 (see page 4)
Installation (see page 5)
Step 1 — Installing the Junction Boxes (see page 5)
Step 2 — Connecting Cables to the Units (see page 6)
Partition status signal via eBUS (see page 7)
Partition status signal via I/O Ports (see page 8)
Step 3 — Setting the BUS ID Addresses (see page 9) only for Control Signal via eBUS
Step 4 — Configuring the System (see page 12)
Step 5 — Testing and Troubleshooting the System (see page 12)
Step 6 — Mounting the Transmitter and Receiver (see page 13)
Step 7 — Aligning the Transmitter and Receiver (see page 13)
Before You Start
Downloading Software
If you are sending the partition status signal via eBUS or if you are using digital output ports connected to an Extron IPCP Pro
control processor, download the latest versions of Extron Global Congurator Plus and Professional or Global Scripter. You can
use Global Congurator to congure the system or Global Scripter to program the system.
If you are using digital output ports connected to other Extron control products, download Global Congurator 3.0.
See the appropriate help le for information about using the software.
To download the software:
1. Go to www.extron.com.
2. Click (see gure 3, 1).
3. Click (2).
Figure 3. Downloading Software

Produkspesifikasjoner

Merke: Extron
Kategori: Ikke kategorisert
Modell: ECM S10

Trenger du hjelp?

Hvis du trenger hjelp med Extron ECM S10 still et spørsmål nedenfor, og andre brukere vil svare deg




Ikke kategorisert Extron Manualer

Ikke kategorisert Manualer

Nyeste Ikke kategorisert Manualer