Side 1/16

Please read instructions carefully before installing
Veuillez lire les instructions attentivement avant d’installer le produit
Lea cuidadosamente las instrucciones antes de instalar
Array Signal Sensor Puck
Capteur de signaux réseau
Disco de sensor de señales de la matriz
INSTALLATION GUIDE AND OWNER’S MANUAL
GUIDE D’INSTALLATION ET MANUEL DU PROPRIÉTAIRE
GUÍA DE INSTALACIÓN Y MANUAL DEL PROPIETARIO

TOOLS REQUIRED FOR INSTALLATION (NOT INCLUDED)
PARTS PROVIDED FOR INSTALLATION
PRODUCT SPECIFICATIONS
• # 8 screws (2X)
• Drywall anchors (2X)
• AC Adapter (1X)
• Electric drill, ” drill bit¼
• # 2 Phillips screw driver
• Level
• Measuring tape
ENGLISH
WARNING: Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire:
IMPORTANT CAUTIONS AND INSTRUCTIONS FOR USING PRODUCT:
*For a copy of the manual please visit fellowes.com
Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain this product.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage. Retain instructions for future use.
IMPORTANT SAFETY INSTRUCTIONS — Read Before Using!
Dimensions 1.7 x 4.2 x 4.2 in 43 x 107 x 107 mm
Weight of System 0.4 lbs 0.2 kg
AC Input 100-240V 50/60Hz 1.00A
DC Input 5V 4.00A
Power 20W
• Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
• This product is not serviceable. DO NOT attempt to open,
repair, or modify this product. Doing so could present the
risk of electrical shock or other hazard.
• Only use the power cord that was supplied with the
product. Use of unauthorized power cords could result in
electrical shock or product damage.
• Do not use if the power cord is damaged.
• Do not bend the power cable excessively or place heavy
object on top of it.
• When drilling into mounting surface, do not damage
electrical wiring or other hidden utilities.
• Use only the electrical power (voltage and frequency),
specified for this product.
• Do not obstruct the air inlet of the product.
• Do not spray aerosols on, or into the unit.
• Do not use detergent to clean the unit.
• Do not insert liquids or foreign objects into the air intake.
• Do not install this product near heat-generating
equipment.
• Do not use the product near flammable substances or a
gas leak.
• Do not use the unit where it is humid or where the unit
may get wet.
• Do not alter the length of the power cord.
• This product is for indoor use only.

OPTIMAL PLACEMENT
To ensure the best signal strength, we strongly recommend that you avoid installing the sensor puck on or near the following:
• Large metal objects
• Electrical equipment
• Sources of extreme moisture
• Metal stud framing
• Corners
WALL MOUNTING INSTRUCTIONS
Ensure that there is a working outlet with the correct electrical specifications within reach of the installation location. Otherwise
have a qualified electrician install one. Remove Sensor from packaging and record “Web ID” from back for later onboarding.
Determine location for installation. Mark
2 holes 2” apart horizontally, ensuring
they are level. Drill holes.
Align mounting slots with screws.
Maneuver screws into mounting slots and
gently press unit until flat against wall.
Connect power cord to sensor puck and
route cord along guide.
Secure wall plug into outlet. Product will
turn on. After approximately 40 to 60
seconds, the LED will breathe green. After
30s, the LED will show blue for good air
quality, amber for fair air quality, and red
for poor air quality.
Fasten mounting screws into stud or
drywall anchor holes with screwdriver.
Ensure screws are fully seated in
mounting slots by gently moving the
product downward until the slot contacts
the screws.
WIRELESS CONNECTION - GETTING STARTED
MAINTENANCE AND CLEANING
This product has additional features that are only available when using the online dashboard.
Please allow 15 to 20 minutes after powering on for unit to connect to the dashboard.
To get started, please visit arrayviewpoint.fellowes.com
If you have questions or need help along the way, please contact us at 1-800-955-0959
If noticeable dust buildup then use brush attachment to vacuum away any dust.
Do not use canned air as it may damage the internals of the device.
1
4
2
5
3
6
Note: for desktop installation, only steps 3 and 6 are required.
Produkspesifikasjoner
Merke: | Fellowes |
Kategori: | Luftrenser |
Modell: | Array Signal |
Trenger du hjelp?
Hvis du trenger hjelp med Fellowes Array Signal still et spørsmål nedenfor, og andre brukere vil svare deg
Luftrenser Fellowes Manualer

18 Februar 2025

18 Februar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025

21 Januar 2025
Luftrenser Manualer
- Luftrenser Aiwa
- Luftrenser Uniprodo
- Luftrenser Haier
- Luftrenser Sharp
- Luftrenser Electrolux
- Luftrenser Philips
- Luftrenser TCL
- Luftrenser IKEA
- Luftrenser Rikon
- Luftrenser Samsung
- Luftrenser Delonghi
- Luftrenser Imarflex
- Luftrenser Kogan
- Luftrenser Sunbeam
- Luftrenser Panasonic
- Luftrenser Olimpia Splendid
- Luftrenser EMOS
- Luftrenser Clean Air Optima
- Luftrenser Levoit
- Luftrenser Breville
- Luftrenser Trebs
- Luftrenser Be Cool
- Luftrenser Mitsubishi
- Luftrenser MSR
- Luftrenser E.ziclean
- Luftrenser Cuisinart
- Luftrenser Alen
- Luftrenser Guardian
- Luftrenser Dyson
- Luftrenser GermGuardian
- Luftrenser Eldom
- Luftrenser Brentwood
- Luftrenser Philco
- Luftrenser Shark
- Luftrenser Bionaire
- Luftrenser Homedics
- Luftrenser Toshiba
- Luftrenser Innoliving
- Luftrenser Beghelli
- Luftrenser Perfect Aire
- Luftrenser Uni-T
- Luftrenser Arovec
- Luftrenser Aconatic
- Luftrenser InLine
- Luftrenser Honeywell
- Luftrenser Haus & Luft
- Luftrenser Renpho
- Luftrenser Sôlt
- Luftrenser Vicks
- Luftrenser Meaco
- Luftrenser Instant
- Luftrenser Pingi
- Luftrenser Dri Eaz
- Luftrenser TruSens
- Luftrenser Lenoxx
- Luftrenser Winix
- Luftrenser Proficare
- Luftrenser Hacienda
- Luftrenser Crane
- Luftrenser Zepter
- Luftrenser DH Lifelabs
- Luftrenser Festool
- Luftrenser Airpura
- Luftrenser Rolfstone
- Luftrenser TaoTronics
- Luftrenser Teqoya
- Luftrenser Cado
- Luftrenser Airfree
- Luftrenser Kaysun
- Luftrenser Zigma
- Luftrenser Faton
- Luftrenser Bloomfold
Nyeste Luftrenser Manualer

10 April 2025

10 April 2025

9 April 2025

7 April 2025

6 April 2025

4 April 2025

3 April 2025

2 April 2025

1 April 2025