Flojet Triplex 3426 Bruksanvisning

Flojet Varmepumpe Triplex 3426

Les nedenfor 📖 manual på norsk for Flojet Triplex 3426 (4 sider) i kategorien Varmepumpe. Denne guiden var nyttig for 4 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/4
Triplex Diaphragm
3426 / 3526 / 3626 Series
Automatic Water System Pump
FEATURES
Self–Priming
Dry Running
Soft Noise Absorbing Mounts
Snap–in Port Fittings
Built-in Bypass : Less Pulsation
Reduces need for accumulator tank
Corrosion Resistant Materials
Meets ISO 8846 (Ignition protection)
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing
Totally Enclosed. CE Models are
fully suppressed.
Pump: Three chamber diaphragm design
Self-priming up to 9 feet suction lift;
Pump able to run dry without damage Dimensions English (SI)
*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.
OPERATION
With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
trouble shooting guide. CAUTION - Pump surface will get hot to the touch if operated for extended periods of time
under pressurized conditions.
2.25"
3.12"
4.24"
4.75"
3.18"
9.04"
(80 mm) (65 mm)
(229 mm)
(80 mm)
(108 mm)
(121 mm)
DIMENSIONAL DRAWING
Model 3426 / 3526 / 3626 Series
Pump Height Length Width Weight
Series inches (mm) inches (mm) inches (mm) Lb (Kg)
3X26XXX 4.75 (121) 9.00 (229) 6.00 (152) 3.50 (1.59)
MODEL* AMP DRAWVOLTS
@10 psi (0.7 bar)
FLOW
GPM (LPM)
PRESSURE SWITCH
Max psi (bar)
BYPASS
03526144 12V dc 4.4 2.9 (11) 50 (3.4) Yes
R3626344 24V dc 2.2 2.9 (11) 40 (2.8) Yes
R3426144 12V dc 4.4 2.9 (11) 25 (1.7) Yes
R3426344 24V dc 2.2 2.9 (11) 25 (1.7) Yes
R3426148 12V dc 3.5 2.0 (8) 25 (1.7) Yes
R3426348 24V dc 1.7 2.0 (8) 25 (1.7) Yes
C
A
B
Red (+)
Fuse
(+)
Switch
Battery
Black ( )
-
)
-
)
INSTALLATION WIRING
STEP 1
Remove shipping plugs from pump ports. Some water
from factory testing may spill out.
STEP 2
Connect fittings supplied with the pump to the RV’s
plumbing. Use 1/2’ I.D. Flexible hose (preferably braided
or reinforced) to reduce vibration through the plumbing
system as shown on Fig. 1. Use hose clamps on the
slip-on barb hose connectors.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first then pump
head mounts, while supporting weight of pump.
STEP 5
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 6
Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump
inlet.
This strainer or equivalent is required for pump warranty
to be valid.
STEP 1
Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.
STEP 2
Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.
STEP 3
Install a 10 amp fuse protection on the positive lead.
FIG. 1
Note: To help reduce noise and vibration of the pump
through the system use flexible lines on the inlet and
outlet of the pump as shown above. Be sure to use
lines rated to not collapse under pump vacuum.
City Water
Inlet
Check
Valve
Flojet Inlet
Strainer
Water
Heater
Water
Tank
ACCESSORIES
QUICK CONNECT PORT SYSTEM
PUMP PORT x
1/2" MALE QEST.
STRAIGHT
PUMP PORT x
1/2" HOSE BARB
STRAIGHT
PUMP PORT x
3/4" HOSE BARB
STRAIGHT
QUAD PORT x
GARDEN HOSE
STRAIGHT
PUMP PORT x
1/2" MALE QEST.
90 ELBOW°
PUMP PORT x
1/2" HOSE BARB
90 ELBOW°
PUMP PORT x
3/4" HOSE BARB
90 ELBOW°
14
3
2
WARNING: BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM!!
AUTOMATIC WATER SYSTEM PUMP SERVICE PARTS
TROUBLESHOOTING
Failure to Prime - Motor operates, but no pump discharge
Restricted intake or discharge line
Air leak in intake line
Debris in pump
Punctured pump diaphragm (pump leaks)
Crack in pump housing
Motor falls to turn on
Loose wiring connection
Pump circuit has no power
Blown fuse
Pressure switch failure
Defective motor
Pulsating Flow
Restricted pump delivery. Check discharge lines, fittings
and valves for clogging or undersizing
Pump Fails to Turn Off After All Fixtures Are Closed
Empty water tank
Insufficient voltage to pump (low battery)
Punctured pump diaphragm (pump leaks)
Discharge line leak
Defective pressure switch
Low Flow and Pressure
Air leak at pump intake
Accumulation of debris inside pump and plumbing
Worn pump bearing (excessive noise)
Punctured pump diaphragm (pump leaks)
Defective motor
EXPLODED VIEW
The above part numbers are packaged with 2 fittings per bag.
STRAINERS Pump Series Strainer Number Inlet Outlet Screen
3X26XXX 1740012 1/2 Barb Quad Port 40 Mesh
1740002 1/2 Barb 1/2 Barb 40 Mesh
1740004 1/2 M Qest 1/2 M Qest 40 Mesh
1740014 1/2 M Qest Quad Port 40 Mesh
KEY# DESCRIPTION 3426XXX 3526XXX 3626XXX
1 Pressure Switch 2091025 2091050 2091040
2 Pumphead Assembly 20406047A (2.9 gpm) 20406045A 20406046A
20406048A (2.0 gpm)
3 Check Valve Assembly 20407034 20407034 20407034
4 Slide Clips (Pair) 21000407A 21000407A 21000407A

Produkspesifikasjoner

Merke: Flojet
Kategori: Varmepumpe
Modell: Triplex 3426

Trenger du hjelp?

Hvis du trenger hjelp med Flojet Triplex 3426 still et spørsmål nedenfor, og andre brukere vil svare deg




Varmepumpe Flojet Manualer

Varmepumpe Manualer

Nyeste Varmepumpe Manualer