Friedrich PDH09R3SG Bruksanvisning
Friedrich
Air condition
PDH09R3SG
Les nedenfor 📖 manual på norsk for Friedrich PDH09R3SG (37 sider) i kategorien Air condition. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/37

Installation and Operation Manual
THE E XP ERTS IN RO OM AI R CONDI T IONIN G
230 VOLT PDH09K3SGR3, PDH12K3SGR3
265 VOLT PDH09R3SGR3, PDH12R3SGR3
Chassis Models
ZoneAire Premier® R-32 Series
PTAC
Packaged Terminal Air
Conditioners & Heat Pumps

2
US
C
A. IMPORTANT SAFETY AND GENERAL INFORMATION .................3
A.1 Introduction 3 .............................................................................
A.2 • Safety Warnings 3 ...................................................................
A.3 Warning For Using R32 Refrigerant 5 .....................................
A.4 Importance of a Quality Installation 7 .....................................
A.5 Product Inspection 7 .................................................................
A.5 Model Identification Guide 7 .....................................................
A.6 Unit Features 7 ...........................................................................
B. SPECIFICATIONS ................................................................................. 9
B.1 Major Components and Dimensions 9 ....................................
B.2 Product Data Information 9 .....................................................
C. INSTALLATION OF THE UNIT ...........................................................10
C.1 Pre-Installation Checkpoints 10 ...............................................
C.3 Choosing a Location 11 ..............................................................
C.4 Install Unit 13 .............................................................................
C.4.2 External Drain Kit Installation 14 .........................................
C.4.3 Wall Sleeve Installation Instructions (PDXWS) ..............................15
C.4.4 Standard Grille Instructions 19 .............................................
C.5 Chassis Install 20 .......................................................................
E. ELECTRICAL ........................................................................................22
E.1 Electrical Safety Information 22 ...............................................
E.2 Power Cord LCDI Test 22 .........................................................
E.3 Electrical Wiring ...........................................................................................23
E.4 How To Connect 25 .....................................................................
F. REMOTE THERMOSTATS...................................................................26
F.1 Install Thermostat ........................................................................................26
F.2 Terminal Connections 27 ...........................................................
J. STARTUP AND OPERATION ..............................................................27
J.1 Final Inspection 27 .....................................................................
J.2 Air Flow Selection and Adjustment 28 ....................................
J.3 Dip Switches 29 ..........................................................................
J.4 Control Panel Operation 30 .......................................................
J.5 Allocation Mode 31 .....................................................................
M. TROUBLESHOOTING .........................................................................32
M.1. Troubleshooting Tips 32 ......................................................
M.2 Diagnostic Codes 33 .............................................................
P. ACCESSORIES .....................................................................................34
R . INFORMATION FOR THE OWNER ...................................................36
R.2 Routine Maintenance 36 ...........................................................
R.3 Qualification Of Workers 36 ......................................................
R.3 Warranty 37 ................................................................................
CAUTION: Do Not Operate Equipment During Active Stages Of Construction
To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active
stages of completing framing, drywalling, spackling, sanding, painting, flooring, and moulding in the equipment’s designated conditioning
space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of
our standard warranty guidelines. The operation of newly installed equipment during construction will accelerate the commencement and/or
termination of the warranty period.
Register your Air Conditioner
Model information can be found on the name plate.
Please complete and mail the owner registration card furnished
with this product, or register online at www.friedrich.com.
For your future convenience, record the model information .
Model Number ________________________
Serial Number ________________________

3
A. IMPORTANT SAFETY AND GENERAL INFORMATION
A.1 Introduction
This booklet contains the installation and operating instructions for your Air Conditioning unit. There are some precautions that should be taken
to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions.
Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation. Give this booklet
to the owner and explain its provisions. The owner should retain this booklet for future reference.
A.2 Safety Warnings•
WARNING: The manufacturer’s warranty does not cover
any damage or defect to the air conditioner caused by the attachment
or use of any components, accessories or devices (other than those
authorized by the manufacturer) into, onto or in conjunction with the
air conditioner. You should be aware that the use of
unauthorized components, accessories or devices may
adversely affect the operation of the air conditioner
and may also endanger life and property. The
manufacturer disclaims any responsibility for such loss
or injury resulting from the use of such unauthorized
components, accessories or devices.
WARNING:Electrical Shock Hazard
Disconnect all power to the unit before starting maintenance. All
electrical connections and wiring MUST be installed by a qualified
electrician and conform to the National Code and all local codes
which have jurisdiction. Failure to do so can result in property
damage, severe electrical shock or death.
WARNING: Read Installation Manual
Please read this manual thoroughly prior to equipment
installation or operation. It is the installer’s resposibility
to properly apply and install the equipment. Installation
must be in conformance with the NFPA 70-2023 national
electric code or current edition, International Mechanic
code 2021 or current edition, and any other local or
national codes.
WARNING: Safety First
Do not remove, disable, or bypass this unit’s safety
devices. Doing so may cause fire, injuries, or death.
WARNING ADVERTENCIA ATTENTION
• RISK OF FIRE OR
EXPLOSION
• FLAMMABLE REFIGERANT
USED
• REPAIRS MAY ONLY BE
PERFORMED BY TRAINED
PERSONNEL
• CONSULT SERVICE
MANUAL BEFORE
ATTEMPTING REPAIRS. ALL
SAFETY PRECAUIONS MUST
BE FOLLOWED
• DO NOT PUNCTURE
TUBING
• DISPOSE OF UNIT
PROPERLY IN ACCORDANCE
WITH FEDERAL OR LOCAL
REGULATIONS
• ONLY USE A2L APPROVED
SERVICE EQUIPMENT
• RIESGO DE FUEGO
• REFIGERANTE INFLAMABLE
UTILZADO
• PARA SER REPARDO
UNICAMENTE POR PERSONAL
DE SERVICIO CAPACITADO
• CONSULTE EL MANUAL
DE REPARACION DEL
PROPIETARIO ANTES
DE INTENTAR REPARAR
ESTE PRODUCTO. SE
DEBEN SEGUIR TODAS
LAS PRECAUCCIONES DE
SEGURIDAD
• NO PERFORE LA TUBERIA
DE REFIGERANTE
• DESECHE
APROPIADAMENTE DE
ACUERDO CON LAS
REGULACIONES FEDERALES
O LOCALES
• RISQUE D’INCENDIE
• REFRIGERANT
INFLAMMABLE UTILISE
• A REPARER UNIQUEMENT
PAR DU PERSONNELDE
SERVICE QUALIFIE
• CONSULTAR LE MANUEL
DE REPARATION/GUIDE
DU PROPRIETARE AVANTE
DE TENTER DE REPARER
CE PRODUIT. TOUTES LES
PRECAUTIONS DE SECURITE
DOIVENT ETRE SUIVIES
• NE PAS PERFORER LE
TUYAU DE REFIGERANT
• ELIMINER CORRECTEMENT
CONFORMENT AUX
REGLEMENTS FEDERAUX OU
LOCAUX
Produkspesifikasjoner
Merke: | Friedrich |
Kategori: | Air condition |
Modell: | PDH09R3SG |
Trenger du hjelp?
Hvis du trenger hjelp med Friedrich PDH09R3SG still et spørsmål nedenfor, og andre brukere vil svare deg
Air condition Friedrich Manualer

30 Desember 2025

16 Oktober 2024
Air condition Manualer
- Air condition Thomson
- Air condition Amana
- Air condition Whirlpool
- Air condition Haier
- Air condition NewAir
- Air condition LG
- Air condition Bosch
- Air condition BEKO
- Air condition Hisense
- Air condition Arcelik
- Air condition Danby
- Air condition Gree
- Air condition TCL
- Air condition Hotpoint
- Air condition Cecotec
- Air condition Samsung
- Air condition Delonghi
- Air condition Comfee
- Air condition Kogan
- Air condition SereneLife
- Air condition Create
- Air condition Furrion
- Air condition Midea
- Air condition Sauber
- Air condition Candy
- Air condition Orbegozo
- Air condition Panasonic
- Air condition Olimpia Splendid
- Air condition Westinghouse
- Air condition Sencor
- Air condition Fujitsu
- Air condition Orava
- Air condition Mistral
- Air condition Khind
- Air condition CyberPower
- Air condition Whynter
- Air condition GE
- Air condition Hyundai
- Air condition VänEE
- Air condition Ausclimate
- Air condition Infiniton
- Air condition Lavorwash
- Air condition Omega Altise
- Air condition Daikin
- Air condition Be Cool
- Air condition Einhell
- Air condition Avidsen
- Air condition Mitsubishi
- Air condition Tristar
- Air condition Eldom
- Air condition Elba
- Air condition Philco
- Air condition REMKO
- Air condition Vivax
- Air condition Black And Decker
- Air condition Heinner
- Air condition SEEGER
- Air condition Meireles
- Air condition IFB
- Air condition Profilo
- Air condition Middle Atlantic
- Air condition Duracraft
- Air condition Home Electric
- Air condition Milectric
- Air condition LERAN
- Air condition Perfect Aire
- Air condition Argoclima
- Air condition Svan
- Air condition ARCTIC WIND
- Air condition Trisa
- Air condition Daizuki
- Air condition Mayer
- Air condition HTW
- Air condition Be Quiet!
- Air condition BOSFOR
- Air condition KDK
- Air condition Aconatic
- Air condition AireMax
- Air condition Profile
- Air condition Keystone
- Air condition Honeywell
- Air condition Theben
- Air condition Ravanson
- Air condition Yamazen
- Air condition ActronAir
- Air condition Orima
- Air condition Woods
- Air condition Aspes
- Air condition Soler & Palau
- Air condition Bavaria
- Air condition Dantherm
- Air condition Sôlt
- Air condition Daitsu
- Air condition Fuave
- Air condition Proklima
- Air condition Universal Blue
- Air condition Rinnai
- Air condition Symphony
- Air condition Kelvinator
- Air condition Premium
- Air condition Corona
- Air condition Krone
- Air condition Royal Sovereign
- Air condition Gutfels
- Air condition Duux
- Air condition GoldAir
- Air condition Heller
- Air condition Teco
- Air condition Magnavox
Nyeste Air condition Manualer

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

16 Januar 2025

15 Januar 2025