GENERAL Life HT270S Bruksanvisning
GENERAL Life
Termostat
HT270S
Les nedenfor 📖 manual på norsk for GENERAL Life HT270S (4 sider) i kategorien Termostat. Denne guiden var nyttig for 5 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/4
ROOM THERMOSTAT
Button Functions
Product Display Layout
Note: During active use of the room thermostat, the symbols indicated by 2, 3, 4, 6
and 7 will not appear on the screen.
RECEIVER
RECEIVER LED DESCRIPTIONS
ROOM THERMOSTAT PLACEMENT
The room thermostat needs to be placed in the room which is used most frequently.
For instance; the living room or lounge. Placing the room thermostat in a spot that
has air circulation like the entrance of a room or the side of the window should be
avoided. Also anywhere close to heating/cooling units such as a radiator, stove, and
spots that get direct sun lights would not be suitable. The room thermostat needs to
be located above the floor 150 cm in height. Few trials may be made to find the most
convenient spot.
WHAT IS A SMART ROOM THERMOSTAT?
A smart room thermostat is a device that allows you to control your heating
equipment via APP with the internet even when you are not at home.
HOW DOES SENNA 270S SMART WORK?
SENNA 270S SMART is a smart wireless room thermostat. You can control it with
the mobile application after you pair your room thermostat with the receiver, and
complete the installation of the smart receiver.
WHAT ARE THE ADVANTAGES OF SENNA 270S SMART?
You can control your home's temperature via its mobile application, no matter
where you are in the world.
You can easily create daily and weekly schedules via its mobile application.
You can place the room thermostat anywhere in your home, thanks to its use with
batteries.
It ensures that your living space stays at the desired temperature at any time. In
this way, you can save up to 30% on your bills by preventing your heating unit from
working unnecessarily.
RULES THAT NEED TO BE OBSERVED FOR SAFETY
1- Be sure to read the user manual before using the device and its equipment.
2- Opening, disassembly, or use of plastic parts of the product and equipment other
than the intended purpose are out of warranty.
3- Please make sure that the sockets to which you connect your devices and
equipment are at the recommended voltage value in the user manual.
4- Keep away and protect your product and its equipment from all kinds of external
substances such as liquid, dust, heat, etc.
5- Do not expose the device cables to any jamming and pressure. Take care to
connect the devices' energy connection to the sockets you can always reach.
6- Turn off the electrical power to prevent damage to your device and apparatus in
case of lightning and thunderstorms.
7- Turn off the electrical power when your device is not used for a long time.
8- Your devices and equipment should be used by paying attention to the matters
stated in the user manual. In case of damage and malfunctions, arising from
improper use (contact with liquid, falling to the ground, etc.) definitely ask for the
installer's help.
9- Call our service for maintenance and repair of SENNA 270S SMART and its
equipment. Maintenance and repair of the device and equipment should be carried
out only by the technical service of ISIPARK A.S. and its authorized services, spare
parts, and accessories specified by the company should be used.
SENNA 270S SMART and EQUIPMENT
TECHNICAL DATA
Room Thermostat
Receiver
If the pairing is successful, the fast red flashing LED on the receiver will be steady.
The receiver and room thermostat have been paired with each other.
SMART RECEIVER SETUP
For smart receiver setup, download the Smart Life application from App Store or
Google Play or scan the QR code below with your smartphone. In this way, you will
be able to download the Life mobile application from App Store or Google Smart
Play to your smartphone. (You may be required to have a QR code reader
application depending on the brand and model of your phone, for this process.)
Complete the user registration process by opening the mobile application that
you downloaded.
Open the Bluetooth from your mobile phone's settings.
After you completed the user registration process, press the “+” button in the top-
right corner of the main screen of the application, Press the receiver's Wi-Fi
pairing button for 5 seconds.
The LED on the receiver will start to blink green.
Setup will begin with Bluetooth in the application. When the device is found, press
the “Add” button.
Press the “+” button near the W Modem device and press the “ ” button after Next
making sure that you entered the correct Wi-Fi information.
Wait until the setup process is completed. When you saw the green approval
symbol on the W Modem, press the “ ” button in the top-right corner.Done
ROOM THERMOSTAT TEMPERATURE CALI BRATION
Temperature sensors which are used in room thermostats are highly sensitive.
You may need to calibrate your room thermostat if you would like to get the same
temperature values as other thermometers in your living space.
While your device is turned off, press the “ON/OFF” button for 3 seconds.
Press the "ON/OFF" button until the “ ” menu appears. To see the desired
temperature, set the temperature difference by pressing the “Temperature
Adjustment Buttons”. This value can be arranged between “-8° C" and “+8°C".
To save the settings and exit, press the " ON/OFF " button until the device turns
off.
o
Note: Recommended temperature calibration is “0.0 C”.
ROOM THERMOSTAT HYSTERESIS POSITIVE M ENU
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room
thermostat will send a signal to your heating/cooling unit. For instance, when you
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on
the heating mode your heating unit will stop working; on the cooling mode your
cooling unit will start working. To change the hysteresis positive setting:
While your device is turned off, press and hold the “ON/OFF” button for 3 seconds.
Press the “ON/OFF” button until the “ ” menu appears.
Adjust the operating sensitivity by using the “Up” and “Down” buttons in the “ ”
hysteresis positive menu.
To save the settings and exit, press the "ON/OFF" button until the device turns off.
Changes have been saved. Your room thermostat will be working with set
operating sensitivity when you open your device.
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
The hysteresis negative factory setting of your room thermostat is -0.5°C. This
value may be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative
value is -0.5°C, if the room temperature goes below 0.5°C of the set temperature,
your room thermostat will send a signal to your heating/cooling unit. For instance,
when you set your room thermostat to 22°C, if the room temperature goes below
21.5°C, on the heating mode your heating unit will start working; on the cooling
mode your cooling unit will stop working. To change the hysteresis negative
setting:
While your device is turned off, press and hold the “ON/OFF” button for 3 seconds.
Press the “ON/OFF” button until the “ ” menu appears.
Adjust the operating sensitivity by using the “Up” and “Down” buttons in the “ ”
hysteresis negative menu.
To save the settings and exit, press the "ON/OFF" button until the device turns off.
Changes have been saved. Your room thermostat will be working with set
operating sensitivity when you open your device.
1 2 3
ENGLISH
SENNA 270S SMART USER MANUAL
4
generallife.com.tr
2 3 4
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
SENNA 270S SMART
Room Thermostat Alkaline
Battery
Holder Dowels and
Screws
Receiver
85mm / 125mm / 20mm
3V DC (2 x AAA Alkaline Battery)
o
0.1 C
o o
(-2.0 C) – (+2.0 C)
o o
(5 C) – (40 C)
1 Year (2 x AAA)
o o
(-10 C) – (+50 C)
o o
(-20 C) – (+60 C)
Dimensions (H/L/W)
Operating Current
Temperature Measurement Accuracy
Operating Sensitivity
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
90mm / 90mm / 25mm
230V AC
7A (240VAC – Resistive Load)
10A (120VAC – Resistive Load)
o o
(-20 C) – (+60 C)
Dimensions (H/L/W)
Operating Current
Relay NO Switching Current
Storage Temperature
BATTERY PLACEMENT
Press the screwdriver forward from the space at the bottom of the room thermostat,
bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in
the battery housing with the correct battery direction. Replace both batteries at the
same time. Align the front part of your room thermostat with the corresponding slot
on the back, and then push gently until the thermostat snaps into place.
Low Battery Warning: When the “ ” icon appears on the screen, it means “low
battery warning”. It is recommended to replace the batteries when this warning
appears.
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty. Please throw your dead batteries into the waste bin for batteries.
RECEIVER PLACEMENT
The important things to note for the Receiver placement are
avoiding physical contact between the receiver and the
heating/cooling unit, and protecting it against materials such
as liquid, dust, etc.
The devices should be placed to minimize the damage to the received and
transmitted signals by paying attention to the following points;
The devices should not be mounted on metal surfaces.
The devices should not be installed close to electrical cables and electronic
equipment such as computers and television units.
The devices should not be installed near large metal structures or other building
materials using fine metal meshes such as special glass or special concrete.
Distance between the room thermostat and the Receiver should not exceed 20
meters or 2 floors.
The receiver must be installed at least 50 cm away from the heating/cooling unit.
RECEIVER INSTALL ATI ON
First, shut down your heating/cooling unit and your heating/cooling unit's power
source with all electrical current (fuse, socket, etc.)
As shown in the connection diagram, connect one end of the heating/cooling unit
connection cable to the COM and the other to the NO input of the receiver.
Connect the other ends of the cable -which you connected to the receiver- to the
room thermostat connection terminal as shown in your heating/cooling unit's
user manual.
You must first connect the receiver power cable to the receiver and then to the
fuse to which the heating/cooling unit is connected.
After completing the cable connection process, first, turn on your fuse and then
your heating/cooling unit.
Finish the installation of the room thermostat to pair the receiver with the room
thermostat.
RECEIVER WIRING DIAGRAM
Warning! Operations within the heating/cooling unit or the electrical installation
must be carried out by professionally qualified persons.
PAIRI NG THE ROOM THERMOSTAT WITH THE RECEIVER
To pair the room thermostat with the receiver, press the “Manual Operation
Button” and “Wi-Fi Pairing Button” together at the same time and see the
receiver's fast blinking red LED.
Press the “ON/OFF” button for 3 seconds while your device is turned off.
Press the “ON/OFF” button until “ ” the pairing menu appears.
Press your room thermostat's “Up” or “Down“ button while the LED is fast blinking
red.
COM
NO
AC
(230V)
HEATING/COOLING UNIT
1-Manual Operation Button:
Deactivates the receiver and allows users to
manually use the heating/cooling unit.
2-Wi-Fi Pairing Button:
Makes the receiver ready for smart installation.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Heating/Cooling Unit Connection Cable Input
4
1
2
3
5
Blinking Red
Fast Blinking Red
Steady Red
Blinking Green
Steady Green
Steady Turquoise
3 Short Red Blinking
3 Short Green Blinking
Blinking Red and Green
The receiver did not get any signal from the heating/
cooling unit for 22 minutes or longer and the heating/
cooling unit has shut down.
Waiting for a pairing signal from the room thermostat.
The receiver and the room thermostat have been paired.
Smart installation has not been completed.
The receiver is in Bluetooth searching mode.
Smart installation has been completed.
The heating/cooling unit is not working.
The heating/cooling unit is working.
Shut the heating/cooling unit down signal has reached
the receiver.
Operate the heating/cooling unit signal has reached the
receiver.
The heating/cooling unit is working in manual mode.
ON/OFF and Setting Button
Economy Mode
Comfort Mode
Heating/Cooling Modes (Press and hold for 5 seconds.)
Temperature Adjustment (Increasing)
Temperature Adjustment (Decreasing)
1
2
3
4
5
6
Room Temperature
Set Temperature
Economy Mode
Comfort Mode
Battery Indicator
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
7
Click to download.
SMART ROOM THERMOSTAT
OPEN WINDOW DETECTION FEATURE
Your room thermostat measures sudden temperature changes in your house with
its open window detection feature and prevents unnecessary energy consumption
by turning off the heating/cooling unit.
The room thermostat is switched to heating mode while the detection is active. If a
decrease in room temperature of more than 5 degrees is detected within 15
minutes, the room thermostat switches to the alarm state and turns off the heating
system.
The heating unit remains switched off for 10 minutes unless manual intervention
is performed on the room thermostat. A warning appears on the mobile
application that an open window has been detected. The heating unit is activated
at the end of 10 minutes. If the room thermostat detects that the window is
closed, the heating unit continues to work. If the temperature continues to drop,
the heating unit is turned off again.
If the room Thermostat is operated in cooling mode, a sudden temperature rise is
taken into account.
This feature can be enabled/disabled from the room thermostat settings:
Press the “ON/OFF” button for 3 seconds while your device is turned off.
Press the “ON/OFF” button until the “ ” menu appears.
Press the “Up” or “Down” button while in the “ ” menu to choose the “ ” or
“ ” option and press the “ON/OFF” button.
To save the settings and exit, press the “ON/OFF” button until the device turns off.
The settings you have made are saved. Your device will work with the setting you
have made when you open it.
FACTORY SETTING RESET
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting, heating/cooling modes,
and hysteresis settings to the factory setting. To reset your room thermostat to
factory setting:
While your device is turned off, press the “ ”ON/OFF button for 3 seconds.
Press the “ON/OFF” button until the “ ” menu appears.
While in the “ ” menu, select the “ ” option by using the “+” or “-” buttons
and press the “ON/OFF” button.
Your device will be turned off and reset to factory settings.
MODE SETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode and “ ”
Economy Mode . Modes work according to the pre-set temperature values “ ”
adjusted by user.
In order to change the comfort mode temperature value;
Press and hold the comfort mode button for 3 seconds.
Change the temperature value by pressing “+” or “-“ buttons.
Press the comfort mode button once to save the changes you have made or wait
10 seconds.
In order to change the economy mode temperature value;
Press and hold the economy mode button for 3 seconds.
Change the temperature value by pressing “+” or “-” buttons.
Press the economy mode button once to save the changes you have made or wait
10 seconds.
You can use the “+” and “-” buttons to use the Room Thermostat manually.
ROOM THERM OSTAT WORKING LOGIC
Heating Mode
Your room thermostat takes the average room temperature of the last 40 seconds
as the basis. If the room temperature goes above the hysteresis positive
temperature value you set, your room thermostat will stop the heating unit. If it goes
below the hysteresis negative temperature value, your room thermostat will start
the heating unit. Thus, it ensures that the room temperature remains within a
certain range.
Cooling Mode
Your Room Thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will start the cooling unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will stop the cooling
unit. Thus, it ensures that the room temperature remains within a certain range.
Your Room Thermostat sends the last status signal to the Receiver every 3 minutes.
Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver does not operate the heating/cooling unit until 'operate' signal reaches
from the Room Thermostat. However, in this case, if the Room Thermostat
continues to operate normally, it will continue to work properly without any need for
intervention since it sends a status signal to the Receiver every 3 minutes.
FREQUENTLY ASKED QUESTIONS
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating/cooling unit has On-Off connections, your Room Thermostat is
compatible. You can find information about your heating/cooling unit from your
heating/cooling unit operating manual or from your heating/cooling unit service.
How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit
should be made by professionally qualified persons.
2x0.75 mm cable is sufficient for the Receiver – heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
stated in the user manual of your heating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
the Receiver as shown in the "RECEIVER WIRING DIAGRAM" section.
The direction of the cable ends does not matter.
DECL AR ATI ON OF C ON FO RM ITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specifications below is covered by the provisions of the mentioned directive.
Brand
Product Name
Product Type
The product manufactured by ISIPARK and mentioned above is connected
wirelessly at 2.4 Ghz internet and periodically shares the temperature and status
information with the server on the internet.
Compatible Directives:
Radio and Telecommunications Terminal Equipment Regulation
2014/53/EU (ETSI EN 301 489-1 V2.2.3 (2019-11),
ETSI EN 301 489-17 V3.2.4 (2020-09), EN 300 220-1 V3.1.1,
EN 300 220-2 V3.2.1 (2018-06), EN 62479: 2010, EN 62368-1:2014+A11:2017)
Electromagnetic Compatibility Regulation 2014/30/EU
(ETSI EN 301 489-1 V2.2.3, ETSI EN 301 489-3 V2.1.1)
Low Voltage Directive 2014/35/EU (EN 60730-2-9)
Supplementary Information: Mentioned product can be used with combi boilers
with on / off output and compatibility with the directive only covers the product.
ISIPARK is not responsible for the compliance of the entire system with the
directive. This declaration does not apply when changes are made to the product
without obtaining our consent.
5 765 6 7 8
Time
o
17 C
o
22 C
Room
Temperature
15 min. 25 min. 40 min.
Off On On
Heating/Cooling Unit
Time
Heating
Unit Off
Heating
Unit On
Set
Temperature
Room
Temperature
o
22.0 C
o
22.5 C
o
21.5 C
Time
Cooling
Unit Off
Cooling
Unit On
Set
Temperature
Room
Temperature
o
22.0 C
o
22.5 C
o
21.5 C
: GENERAL Life
: SENNA 270S SMART
: Smart Room Thermostat
WARRANT Y CONDITIONS
1- The warranty period starts from the invoice date and warranted against
manufacturing defects for 2 years.
2- Devices and apparatus are delivered to the customer in working condition in
our company. On-site commissioning is subject to a service fee.
3- The repair of the devices and apparatus covered by the warranty is carried
out in our company factory and should send by contracted transportation
company. In on-site services, the transportation and accommodation
expenses of the service personnel belong to the customer. The shift fee during
transportation is added to the service fee and collected in advance.
4- The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belongs to
the customer.
5- In case of malfunctioning of the devices and apparatus whose warranty
period continues, it is tested in our company whether the malfunction is
caused by a customer or manufacturer fault, and it is reported with a report
issued by our company.
6- In case of detection of manufacturer-induced errors of devices and
apparatus whose warranty period continues, the customer can request a
replacement or repair of the devices and apparatus at full expense by the
manufacturer, unless it's higher than the product's price.
7- In the event that the faults of the devices and apparatus whose warranty
period continues are determined as caused by the customer, all expenses
would be belong to the customer.
8- Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts.If customer do not warn
manufacturer with knowledge of damage, customer lose the rights of article 6.
9- Malfunctions resulting from the use of devices and apparatus contrary to the
matters stated in the User Manual are not covered by the warranty.
10- Devices and their apparatus are out of warranty if they are beaten, broken or
scratched by the customer.
11- Damages resulting from the use of devices and apparatus belonging to
other brands and models without the approval of the manufacturer are not
covered by the warranty.
12- Battery leakage and errors due to rust, oxidation and liquid contact by
working in acidic / humid environments are not covered by the warranty.
13-When the product is not used for a long period (more than 15 days), remove
the batteries. Otherwise, malfunctions that will occur are out of warranty.
14- Damages that may occur during the transportation of devices and
apparatus are not covered by the warranty. Customers can take a
transportation insurance.
15- Damages caused by mains voltage / faulty electrical installation are not
covered by the warranty.
16- Devices and apparatuses are out of warranty for malfunctions caused by
force majeure such as fire, flood, earthquake etc.
17- All of the devices and apparatuses, including all their parts, are under the
warranty of our company.
18- In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repairment period is added to the warranty period.
The repair period of the product cannot exceed 20 working days. This period
starts from the date of notification to the service station of the malfunction
related to the product or, in the absence of a service station, to the seller, dealer,
agency, representative, importer or manufacturer of the product. Consumer
can report the problem by; phone, fax, e-mail, registered and reply paid letter or
a similar way. However, in case of a conflict, responsibility of prove is belong to
the customer. If the malfunction of the product is not repaired within 20
working days, the manufacturer-producer or importer; has to allocate another
product with similar features to the use of the consumer until the repair of the
product is completed,
19- Although the consumer uses his/her repair rights,
-If the product breaks down for 4 times in a year or 6 times in warranty duration
and these problems effects main purpose of the product. (starting from
delivery time during warranty.)
-Exceeding the maximum time required for repair,
-In the event that the service station is not available, if it is determined that the
repair of the defect is not possible with the report prepared (in order) by one of
the seller, dealer, agency, representative, importer or manufacturer, a refund or
a price discount at the rate of defect can be requested.
20- The customer can make complaints and appeals to consumer courts or
consumer arbitration committees.
21- The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repair and replacement of devices and apparatus will be made for a fee.
WARRANT Y CERTIFICATE
Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-Mail: generallife@generallife.com.tr
Authorised Signatory:
Company Stamp:
Product
Type: Smart Room Thermostat
Brand: GENERAL Life
Model: SENNA 270S SMART
Guarantee Period: 2 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
Vendor
Title:
Address:
Tel: Fax:
E-Mail:
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
Product
Type: Smart Room Thermostat
Brand: GENERAL Life
Model: SENNA 270S SMART
STAMP
V-01.2023
Isıpark reserves the rights of changing product specifications and user
manuals.
*For all changes,you may visit generallife.com.tr
Produkspesifikasjoner
Merke: | GENERAL Life |
Kategori: | Termostat |
Modell: | HT270S |
Trenger du hjelp?
Hvis du trenger hjelp med GENERAL Life HT270S still et spørsmål nedenfor, og andre brukere vil svare deg
Termostat GENERAL Life Manualer
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
Termostat Manualer
- Termostat ORNO
- Termostat Bosch
- Termostat Boneco
- Termostat Siemens
- Termostat EBERLE
- Termostat Schwaiger
- Termostat AEG
- Termostat TP Link
- Termostat Oreg
- Termostat Netatmo
- Termostat Busch-Jaeger
- Termostat Brennenstuhl
- Termostat Danfoss
- Termostat Somfy
- Termostat Panasonic
- Termostat Schneider
- Termostat EMOS
- Termostat Heatit
- Termostat Dimplex
- Termostat Velleman
- Termostat GE
- Termostat Nexa
- Termostat Nobo
- Termostat Tru Components
- Termostat Bearware
- Termostat Elgato
- Termostat Avidsen
- Termostat STI
- Termostat Hunter
- Termostat Basetech
- Termostat TFA
- Termostat Tesla
- Termostat Renkforce
- Termostat REMKO
- Termostat ATAG
- Termostat Drayton
- Termostat Jung
- Termostat Ambiano
- Termostat Crestron
- Termostat Xavax
- Termostat Techno Line
- Termostat Remeha
- Termostat Heatmiser
- Termostat Wolf
- Termostat Silvercrest
- Termostat AVM
- Termostat HomePilot
- Termostat Elektrobock
- Termostat Corberó
- Termostat Perel
- Termostat Delta Dore
- Termostat Homematic IP
- Termostat Vimar
- Termostat Emerson
- Termostat Salus
- Termostat Fenix
- Termostat Honeywell
- Termostat Junkers
- Termostat Eliwell
- Termostat Grasslin
- Termostat Jumo
- Termostat Enda
- Termostat Orbis
- Termostat Fantini Cosmi
- Termostat Vemer
- Termostat Qubino
- Termostat Theben
- Termostat EQ3
- Termostat Etherma
- Termostat Saunier Duval
- Termostat Gewiss
- Termostat Viessmann
- Termostat Bticino
- Termostat Conrad
- Termostat Econo-Heat
- Termostat Elro
- Termostat Gira
- Termostat Tado
- Termostat Brink
- Termostat Emmeti
- Termostat Itho
- Termostat Bryant
- Termostat Aube
- Termostat Baxi
- Termostat Seitron
- Termostat Amfra
- Termostat Vaillant
- Termostat Carel
- Termostat Buderus
- Termostat Optima
- Termostat Frico
- Termostat UPM
- Termostat Computherm
- Termostat Veria
- Termostat Innogy
- Termostat Nefit
- Termostat ICY
- Termostat Levica
- Termostat Itho-Daalderop
- Termostat Carrier
- Termostat Radson
- Termostat ChiliTec
- Termostat King
- Termostat ACV
- Termostat Landis Gyr
- Termostat Nest
- Termostat Oventrop
- Termostat IMIT
- Termostat Horstmann
- Termostat ELKO
- Termostat Alecto
- Termostat Google
- Termostat Emko
- Termostat Wachendorff
- Termostat MundoControl
- Termostat Otio
- Termostat Rose LM
- Termostat Tylö
- Termostat Sinustec
- Termostat TrickleStar
- Termostat Finder
- Termostat Sygonix
- Termostat Warmup
- Termostat Plugwise
- Termostat Lowes
- Termostat Go Green
- Termostat Drayton Erie
- Termostat Intertechno
- Termostat EQ-3
- Termostat Johnson Control
- Termostat RWE
- Termostat Webasto
- Termostat Tellur
- Termostat OJ ELECTRONICS
- Termostat Zehnder
- Termostat Plieger
- Termostat HomeMatic
- Termostat Eneco
- Termostat VDH
- Termostat Maico
- Termostat Yokis
- Termostat Eurotronic
- Termostat HQ
- Termostat Ouellet
- Termostat THERMAFLEX
- Termostat Truma
- Termostat Wallair
- Termostat AWB
- Termostat PECO
- Termostat Worcester-Bosch
- Termostat 2Heat
- Termostat EasyTemp
- Termostat Hugo Muller
- Termostat Watts
- Termostat Westfalia
- Termostat Oregon Scientific
- Termostat H-Tronic
- Termostat Z-Wave
- Termostat Easy Timer
- Termostat Fibaro
- Termostat SPC
- Termostat Muller
- Termostat Bulex
- Termostat Helios (Amfra)
- Termostat IR-V
- Termostat Eqiva
- Termostat Hager
- Termostat Energenie
- Termostat Thermy
- Termostat Ferroli
- Termostat Niko
- Termostat Stiebel Eltron
- Termostat De Dietrich
- Termostat POER
- Termostat Technoline
- Termostat Magnum
- Termostat Cotech
- Termostat Hornbach
Nyeste Termostat Manualer
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024