Haier QS12WB2BEA Bruksanvisning
Haier
Air condition
QS12WB2BEA
Les nedenfor 📖 manual på norsk for Haier QS12WB2BEA (30 sider) i kategorien Air condition. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/30

READ CAREFULLY.
KEEP THESE INSTRUCTIONS.
Design may vary by model number L’aspect peut varier selon le numéro
de modèle.
El diseño puede variar según el
número de model.
31-5001077 Rev. 0 01-25
Ductless Single Zone with Highwall Indoor Unit
Zone simple sans conduit avec unité intérieure en hauteur
Unidad Interna para Pared Alta sin Conducto y de Zona Única
Installation Manual
Manuel d’installation
Instrucciones de instalación

231-5001077 Rev. 0
ENGLISH
Included Items
PACKAGE CONTENTS ................................................................................................... 2
IMPORTANT SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REQUIREMENTS FOR OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Step 1 - Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Step 2 - Installation of Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Wall Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Step 3 - Installation of Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Step 4 - Safety Switch Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Step 5 - Final Check .................................................................................................18
LIMITED WARRANTY ................................................................................................... 21
TABLE OF CONTENTS
PACKAGE CONTENTS
A. Mounting plate 1 B. Installation template 1 C. Screw suite 1
D. Wireless remote controller and older 1 E. Dry battery AAA 2 F. Copper nuts 2
G. Operation manual 1 H. Installation manual 1 I. Indoor Unit 1

31-5001077 Rev. 0 3
ENGLISH
READ AND SAVE THESE INSTRUCTIONS
WARNING For your safety; the information in this manual must be followed to minimize the risk of re, electric
shock, or personal injury.
• Use this equipment only for its intended purpose as
described in this manual.
• This heat pump must be properly installed in accordance
with these instructions before it is used.
• All wiring should be rated for the amperage value listed on
the rating plate. Use only copper wiring.
• All electrical work must be completed by a qualified
electrician and completed in accordance with local and
national building codes.
• All air conditioners contain refrigerants, which under
federal and/or local law must be removed prior to product
disposal. If you are getting rid of an old product with
refrigerants, check with the company handling disposal.
• These R454B heat pumps systems require that
contractors and technicians use tools, equipment and
safety standards approved for use with this refrigerant.
• DO NOT use equipment certied for R22,R32 or R410A
refrigerant only.
WARNING RISK OF ELECTRIC SHOCK. Could cause injury or death.
• An adequate ground is essential before connecting the
power supply or charging with refrigerant.
• Disconnect all connected electric power supplies before
servicing.
• Aluminum building wiring may present special problems -
consult a qualied electrician.
• The surrounding conditions (ambient temperature, direct
sunlight, and rainwater) shall be noticed during electrical
wiring, with eective protective measures being taken.
• The dedicated branch circuit must be used, and leakage
protector with sucient capacity must be installed.
• Repair or replace immediately all electrical wiring that has
become frayed or otherwise damaged. Do not use wiring
that shows cracks or abrasion damage along its length or
at either end.
• When the unit is in the STOP position, there is still voltage
to the electrical controls.
• Copper wire cable in line with local standards shall be used
as the power line and connector wire.
• Both the indoor unit and outdoor unit shall be reliably
earthed.
• Wiring for the outdoor unit shall be made rst and then the
indoor unit. The air conditioner can only be powered on
after wiring and pipe connection.
WARNING RISK OF FIRE. Could cause injury or death.
• Do not store or use combustible materials, gasoline or other ammable vapors or liquids in the vicinity of this or any other
appliance.
For any service which requires entry into the refrigerant
sealed system, Federal regulations require that the work
is performed by a technician having a Class II or Universal
certication.
IMPORTANT SAFETY INFORMATION
ATTENTION
• Please do not use extension cords in this system.
• Aluminum building wiring may have special problems, please consult a licensed electrician.
• If the unit has the leak detection system installed, the unit must be powered except for service.
Produkspesifikasjoner
Merke: | Haier |
Kategori: | Air condition |
Modell: | QS12WB2BEA |
Trenger du hjelp?
Hvis du trenger hjelp med Haier QS12WB2BEA still et spørsmål nedenfor, og andre brukere vil svare deg
Air condition Haier Manualer

27 Februar 2025

27 Februar 2025

15 Januar 2025

15 Januar 2025

15 Januar 2025

6 Januar 2025

6 Januar 2025

6 Januar 2025

6 Januar 2025

6 Januar 2025
Air condition Manualer
- Air condition Thomson
- Air condition Amana
- Air condition Whirlpool
- Air condition NewAir
- Air condition LG
- Air condition Bosch
- Air condition BEKO
- Air condition Hisense
- Air condition Koldfront
- Air condition Arcelik
- Air condition Danby
- Air condition Gree
- Air condition TCL
- Air condition Hotpoint
- Air condition Cecotec
- Air condition Samsung
- Air condition Delonghi
- Air condition Comfee
- Air condition Kogan
- Air condition SereneLife
- Air condition Create
- Air condition Furrion
- Air condition Midea
- Air condition Sauber
- Air condition Candy
- Air condition Carson
- Air condition Orbegozo
- Air condition Panasonic
- Air condition Olimpia Splendid
- Air condition Vox
- Air condition Westinghouse
- Air condition Sencor
- Air condition Fujitsu
- Air condition Orava
- Air condition Mistral
- Air condition Khind
- Air condition CyberPower
- Air condition Dimplex
- Air condition Whynter
- Air condition GE
- Air condition Hitachi
- Air condition Hyundai
- Air condition VänEE
- Air condition Ausclimate
- Air condition Infiniton
- Air condition Lavorwash
- Air condition Omega Altise
- Air condition Daikin
- Air condition Be Cool
- Air condition Einhell
- Air condition Avidsen
- Air condition Mitsubishi
- Air condition Friedrich
- Air condition Tristar
- Air condition Eldom
- Air condition Elba
- Air condition Philco
- Air condition REMKO
- Air condition Vivax
- Air condition Black And Decker
- Air condition Toshiba
- Air condition Heinner
- Air condition SEEGER
- Air condition Meireles
- Air condition IFB
- Air condition Profilo
- Air condition Middle Atlantic
- Air condition Duracraft
- Air condition Home Electric
- Air condition Milectric
- Air condition LERAN
- Air condition Perfect Aire
- Air condition Argoclima
- Air condition Svan
- Air condition ARCTIC WIND
- Air condition Trisa
- Air condition Daizuki
- Air condition Mayer
- Air condition HTW
- Air condition Be Quiet!
- Air condition BOSFOR
- Air condition KDK
- Air condition Aconatic
- Air condition AireMax
- Air condition Profile
- Air condition Keystone
- Air condition Honeywell
- Air condition Theben
- Air condition Ravanson
- Air condition Yamazen
- Air condition ActronAir
- Air condition Orima
- Air condition Woods
- Air condition Aspes
- Air condition Soler & Palau
- Air condition Bavaria
- Air condition Dantherm
- Air condition Sôlt
- Air condition Daitsu
- Air condition Fuave
- Air condition Proklima
- Air condition Universal Blue
- Air condition Rinnai
- Air condition Symphony
- Air condition Kelvinator
- Air condition Premium
- Air condition Corona
- Air condition Krone
- Air condition Royal Sovereign
- Air condition Gutfels
- Air condition Duux
- Air condition GoldAir
- Air condition Heller
- Air condition Teco
- Air condition Magnavox
- Air condition Fuji Electric
- Air condition Sheffield
Nyeste Air condition Manualer

25 Mars 2025

19 Mars 2025

19 Mars 2025

18 Mars 2025

18 Mars 2025

18 Mars 2025

18 Mars 2025

12 Mars 2025

12 Mars 2025

12 Mars 2025