Hinkley Lighting Plantation 4102BB Bruksanvisning
Hinkley Lighting
Lettelse
Plantation 4102BB
Les nedenfor 📖 manual på norsk for Hinkley Lighting Plantation 4102BB (1 sider) i kategorien Lettelse. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/1
H I N K L E Y L I G H T I N G 12600 Berea Road Cleve land, OH 44111 800.446.5539 / 216.671.3 3 0 0 www.hinkl eyli g h t ing.com
assembly instructions
Family: Plantation Item No. 4102 BB/CB/PZ/PL, 5331 PL
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
1. Prepare gem strap for mounting by threading two screws provided into (A) (B)
back of gull wing bracket of gem strap - see .(A) Drawing 1
• Be sure the holes into which the screws are threaded match the spacing of holes (D)
in the ceiling pan - see .(1) Drawings 1 and 2
2. Mount gem strap to junction box , using the two 1” screws provided.(A) (J) (C) not
Make electrical connections from supply wire to fixture lead wires. Refer to instruction
sheet and follow all instructions to make all necessary wiring connections. (I.S. 18)
Then refer back to this sheet to continue installation of this fixture.
1. Hang the fixture by slipping the holes in the ceiling pan over the screws (D) (1) (B)
in the mounting strap - see .(A) Drawing 2
2. Thread on ball knobs to secure fixture to the ceiling.(F)
1. Before installing glass, fixture can now be lamped accordingly.
2. To install glass, thread nipple into coupling - see .(2) (3) Drawing 3
3. Slip glass over nipple and hold in place.(4) (2)
4. Slip cap over nipple and hold in place.(5) (2)
5. Thread finial onto nipple .(6) (2)
*** The construction of this fixture will be accomplished by first mounting the
mounting strap to the junction box, making all necessary electrical connections,
hanging the fixture from the ceiling, and then installing the glass.
start here
4102
5331
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 2 - Fixture Mounting
Drawing 3 - Glass Installation
B
D
F
J
C
A
1
Note: Maximum wattage for 4102, 5331 fixture is watts per bulb. 60
Drawing 1 - Strap Detail
B
(side view)
gull wing
bracket
B
1
4
3
2
6
5
11.06.08
Produkspesifikasjoner
Merke: | Hinkley Lighting |
Kategori: | Lettelse |
Modell: | Plantation 4102BB |
Trenger du hjelp?
Hvis du trenger hjelp med Hinkley Lighting Plantation 4102BB still et spørsmål nedenfor, og andre brukere vil svare deg
Lettelse Hinkley Lighting Manualer
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
Lettelse Manualer
- Lettelse DeWalt
- Lettelse Hama
- Lettelse Neewer
- Lettelse Hazet
- Lettelse Philips
- Lettelse Schwaiger
- Lettelse IKEA
- Lettelse TP Link
- Lettelse Kogan
- Lettelse GoGEN
- Lettelse Nitecore
- Lettelse Kichler
- Lettelse Integral LED
- Lettelse ET2
- Lettelse Quoizel
- Lettelse Crystorama
- Lettelse Brennenstuhl
- Lettelse Varaluz
- Lettelse FIAP
- Lettelse Aputure
- Lettelse Media-tech
- Lettelse Gemini
- Lettelse Klein Tools
- Lettelse Schneider
- Lettelse Dainolite
- Lettelse Tesy
- Lettelse Martin
- Lettelse EMOS
- Lettelse Sharper Image
- Lettelse Fluval
- Lettelse Ryobi
- Lettelse Nanlite
- Lettelse BeamZ
- Lettelse Maxim
- Lettelse Brandson
- Lettelse Aplic
- Lettelse CSL
- Lettelse Bearware
- Lettelse NUVO
- Lettelse Milwaukee
- Lettelse OttLite
- Lettelse Be Cool
- Lettelse Showtec
- Lettelse Busch + Müller
- Lettelse V-Tac
- Lettelse Infinity
- Lettelse Nedis
- Lettelse Elation
- Lettelse Chauvet
- Lettelse Weeylite
- Lettelse Black Diamond
- Lettelse ESYLUX
- Lettelse Livarno Lux
- Lettelse Casalux
- Lettelse Aqara
- Lettelse Beghelli
- Lettelse Middle Atlantic
- Lettelse Rosco
- Lettelse DeSisti
- Lettelse Astera
- Lettelse EXO
- Lettelse Profoto
- Lettelse GRE
- Lettelse Ikan
- Lettelse Ring
- Lettelse Olight
- Lettelse Perel
- Lettelse Blackburn
- Lettelse Sigma
- Lettelse Rayzr 7
- Lettelse Excello
- Lettelse Vimar
- Lettelse Genaray
- Lettelse Altman
- Lettelse Setti+
- Lettelse Kanlux
- Lettelse ARRI
- Lettelse Osram
- Lettelse Light4Me
- Lettelse GlobalTronics
- Lettelse Lume Cube
- Lettelse Digipower
- Lettelse ETC
- Lettelse Fiilex
- Lettelse Portman
- Lettelse ColorKey
- Lettelse Litepanels
- Lettelse Perfect Christmans
- Lettelse XQ-Lite
- Lettelse Govee
- Lettelse Peerless-AV
- Lettelse Heitronic
- Lettelse Obsidian
- Lettelse Blizzard
- Lettelse LUPO
- Lettelse Enttec
- Lettelse Fotodiox
- Lettelse GVM
- Lettelse Amaran
- Lettelse Halo
- Lettelse HQ Power
- Lettelse Kino Flo
- Lettelse Cateye
- Lettelse Maxxmee
- Lettelse Angler
- Lettelse Raya
- Lettelse Elan
- Lettelse Livex Lighting
- Lettelse Ranex
- Lettelse Fuzzix
- Lettelse COLBOR
- Lettelse Lucide
- Lettelse DIO
- Lettelse Paulmann
- Lettelse Melinera
- Lettelse Yongnuo
- Lettelse Audibax
- Lettelse Hudson Valley
- Lettelse Forte Lighting
- Lettelse Smith-Victor
- Lettelse Zylight
- Lettelse Cineo
- Lettelse Prolycht
- Lettelse AD Trend
Nyeste Lettelse Manualer
16 Januar 2025
16 Januar 2025
16 Januar 2025
16 Januar 2025
16 Januar 2025
16 Januar 2025
15 Januar 2025
15 Januar 2025
14 Januar 2025
14 Januar 2025