Hisense B544E Bruksanvisning
Hisense
Air condition
B544E
Les nedenfor 📖 manual på norsk for Hisense B544E (2 sider) i kategorien Air condition. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/2
Please read the Important Notice in these Installation Instructions
supplied with the product, and perform installation in accordance
with these instructions properly.
Important notice
How to install
1
3
The central control adaptor is a dedicated device that can be
directly connected with the indoor unit for converting
communication protocols and connects the indoor unit to
central control network.
Precautions for arrangement:
Qty.: 1
1. Selecting the location where the appliance is to be installed.
2.Wiring connection
① Connection with indoor unit by connecting cable. As shown in
Fig.1.
Central Control Adaptor
Installation Instructions
Model: B544(E)
1. The design and installation of the central control adaptor should
be performed under the unified planning for central control
system. The installation location of the central adaptor, electrical
distribution and wiring, address assignment, connection with
Modbus monitor and indoor unit should be planned in advance.
2. Cables for central control and distribution lines shall not be too
close to each other or routed in the same conduit. RS-485 bus
should be arranged as far away from interference sources as
possible, especially high voltage interference sources, such as
transformer and frequency converter. For other relevant
precautions, see the requirements for wiring of building
automation system.
3. The equipment on either end of the group control bus must be
provided with terminal-matched resistor.
4. The central control line must be configured as a daisy-chain bus
topology. If a star-type or tree topology is required, it is
recommended to use RS-485 hub and RS-485 repeater.
5. The central control adaptor should be installed close to the
electronic control adaptor of the indoor unit.
6. The baud rate of the adaptor must be set the same with
Modbus/ BACnet monitor.
between the indoor unit and the central control adaptor is 40m,
and the maximum allowable length of RS485 control cable is
1000m.
Please install it in the ceiling and close to the electrical control
of indoor unit.adaptor
Fig. 1 Connection with indoor unit by connecting cable
② Connection of central control communication line, as shown in
Fig. 2.
Fig. 2 Connection of central control communication line
Central control
communication line
Connecting
cable
Clamp
Double-sided
tape
Qty.: 1 Qty.: 2 Qty.: 1
Installation
instructions
Checking accessories
2
Check and confirm that in addition to the central control adaptor
product the following accessories are included in the packaging
box.
Indoor unit connector
Connector for communication
line of wired controller
Hook for fastening
of wiring harness
A+ A+ B- B- A+ A
+ B- B -
Twin function terminal
Modbus/B ACnet
function terminal
7. The addresses for the central control adaptor should not be
repeated.
8. The maximum allowable length of the connecting cable
Type
Minimum specifications
Central control
communication
line
Shielded
twisted pairs
Cross-sectional 2
area: 2 0 75mm× .
3. Setting of DIP switches
Please set DIP switches according to the actual conditions.
Settings after power on will not take effect.
Methods for setting DIP switches:
Before setting, slide down the cover on the central control
adaptor. After setting, reinstall the cover to adaptor. As shown in
Fig.3.
Fig. 3 Methods for setting DIP switches
Sliding cover
Notes:
1. The above requirement for wiring is the minimum;
2. The central control communication line should be provided by users;
3. Correct polarity of the cable should be ensured during connection;
4. The cable should be reliably secured after connection is completed.
System
DIP
switch
Description
Setting method
Twin
system
S1 1-
S1-2
Indoor unit
setting
(hardware)
00: Slave Indoor
11: Master Indoor
S1-3
Setting for
terminal
resistor
Be sure to set the position
of the switch on either end
of the central control
system to “ON”.
S1-4
Setting when
fuse is fail to
work
Set the position of the
switch to “ON” to restore
the fuse.
S4-2
Indoor unit
setting
(software)
0: Slave Indoor
1: Master Indoor
S5
Slave indoor
address/Number
of slave indoors
When the central control
adaptor is set as slave, S5
is set as slave address,
which range is 1-15;
When the central control
adaptor is set as master,
S5 is set as slaves’
number, which range is 1-
15.
4. Securing the adaptor
If necessary, use double-sided tape to secure the central
control adaptor onto the indoor unit after installation.
Note: Symbol “ ” indicates the position of the DIP switch.
ON ON
OFF OFF
S2 S3 S4S1
ON
OFF
ON
OFF
ON
OFF
S6 S7S5
ON
OFF
ON
OFF
ON
OFF
System DIP
switch
Description Setting method
Centralized
control
system
S2-1
Setting for
terminal
resistor
Be sure to set the position
of the switch on either end
of the central control system
to “ON”.
S2-2
Setting when
fuse is fail to
work
Set the position of the
switch to “ON” to restore the
fuse
S3
Setting of
baud rate
00: 9600bps(by default).
01: 19200bps;
10: 38400bps.
S4-3
S4-4
Protocol
selection
00: Not connected to
centralized control syestem
(default setting);
01: BACnet;
10: ModBus.
S6
S7
Setting of
BACnet/
ModBus
addresses
S6: for setting high
address(reserve);
S7: for setting low
addresses.
Range of addresses: 1~255.
ON ONON ON
OF F OF FOF F OF F
00000001 (address: 1)
…
11111111 (address: 255)
Wired
controller
Transmitting cable between
indoor and outdoor unit
Outdoor unit
Indoor unit(master) Indoor unit(slave) Indoor unit(slave) Indoor unit(slave)
A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++
A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++
B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
--
B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
--
Wiring diagram for twin system
NOTE Be sure to insert the connecting cable into the wired controller port :
of indoor unit PCB board.
If you still have any trouble, please contact local service center of
our company for further information.
A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
--
···
···
Version No 2262057, A.
RS485 shielded twisted pairs (with polarity, A+ B-)
S6 S7 S6 S7
Wiring diagram for centralized control
system (BACnet/ModBus)
··· ···
··· ···
RS485 shielded twisted pairs (with polarity, A+ B-)
Central control
adaptor
Modbus/
BACnet
monitor
RS485
Interface
Connecting cable
Indoor unit
Indoor unit
Indoor unit
Indoor unit
A
A
A
AA+
+
+
++
A
A
A
AA+
+
+
++ B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++ B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++
B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++ B
B
B
BB-
-
-
-- B
B
B
BB-
-
-
-- A
A
A
AA+
+
+
++ A
A
A
AA+
+
+
++ B
B
B
BB-
-
-
--
B
B
B
BB-
-
-
--
Central control
adaptor Central
control
adaptor
Central
control
adaptor
Central
control
adaptor
Central control
adaptor Central control
adaptor Central control
adaptor Central control
adaptor
Produkspesifikasjoner
Merke: | Hisense |
Kategori: | Air condition |
Modell: | B544E |
Trenger du hjelp?
Hvis du trenger hjelp med Hisense B544E still et spørsmål nedenfor, og andre brukere vil svare deg
Air condition Hisense Manualer
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
Air condition Manualer
- Air condition Whirlpool
- Air condition Arcelik
- Air condition Gree
- Air condition TCL
- Air condition Hotpoint
- Air condition Cecotec
- Air condition Samsung
- Air condition Delonghi
- Air condition Comfee
- Air condition Kogan
- Air condition SereneLife
- Air condition Create
- Air condition Midea
- Air condition Sauber
- Air condition Candy
- Air condition Panasonic
- Air condition Olimpia Splendid
- Air condition Sencor
- Air condition Whynter
- Air condition GE
- Air condition Daikin
- Air condition Be Cool
- Air condition Avidsen
- Air condition Mitsubishi
- Air condition Tristar
- Air condition Eldom
- Air condition Home Electric
- Air condition Milectric
- Air condition LERAN
- Air condition Perfect Aire
- Air condition Argoclima
- Air condition ARCTIC WIND
- Air condition Trisa
- Air condition Daizuki
- Air condition KDK
- Air condition Aconatic
- Air condition AireMax
- Air condition Profile
- Air condition Keystone
- Air condition Honeywell
- Air condition Ravanson
- Air condition Yamazen
- Air condition ActronAir
- Air condition Woods
Nyeste Air condition Manualer
28 Oktober 2024
28 Oktober 2024
28 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024