Introduction
Your SupraSafe is the latest in Rapid Entry key
control. To fully utilize it’s built-in security features,
we recommend that reasonable care be given to the
location and method of mounting.
The vault is coated with a tough, baked polyurethane
abuse; however, it is always best to locate the vault
in an area which is sheltered from excessive moisture
and possible mechanical damage.
Important! Contact your local
department for mounting location
and instructions.
Installation for Supra-Max, SupraSafe
1, SupraSafe 2HS/2HSR, and Supra-
Safe 2HS/TS-Vault
1. Mount the vault so that the moisture drain hole is
on the bottom.
2. Use a level to plumb the vault square.
3. Four 5/16-inch lag bolts have been provided for
surface mounting the vault.
Important! When installing the vault, do not
over-tighten the four mounting bolts as this
may distort the outside shell of the vault.
4. To secure the vault to a masonry/brick wall, it
is necessary to use the anchors provided with
the 5/16 lag bolts mounting kit. Drill a 1/2” hole
approximately 1-3/4” deep into the masonry/brick
wall. It is recommended to use a carbide/masonry
bit to prevent cracking or shattering. Gently pound
the anchor into the hole with a hammer so that it is
5. Caulk between the vault and the wall for better
6.
once the vault has been installed.
7. We strongly recommend the wiring of the tamper
or licensed electrician. The circuit shall conform to
NEC class 2 or 3, or UL class 634 standards. In no
case shall the wiring supply more than 30 volts at
50 ma. Consult local codes and ordinances prior to
installations.
Figure 1. Side View of Mounted Vault
Drain hole
Chain mounting
bracket
P/N 10102664P1 • Feb 2013
© 2013 Kidde. All rights reserved.
Ra trypid En Systems
In llsta ation Instructions
Instructions for SupraSafe 2HSR and
SupraSafe 2HSR/TS Vaults
The SupraSafe 2HSR and SupraSafe 2HSR/TS vaults
are designed to be recessed into a wall for attractive
ush mounting. These units can be adapted to t a
variety of hollow wall situations or can be installed in
a sold concrete wall which has been cored to a six
inch diameter. For concrete or masonry walls in new
construction, we recommend the use of our Cast-in-
Place Mounting Kit described below.
With the SupraSafe 2HSR/TS, removal of the tamper
switch is not necessary during installation. The alarm
wiring to the tamper switch should be pulled tight
so that any attempt to force the vault out of the wall
will break the wire or pull terminals loose. Push-On
type terminals are supplied for connection to tamper
switch. Tamper switch can be connected for either
open or closed circuits.
Cast-in-Place Mounting Kit (P/N: 454000)
The Cast-in-Place Mounting kit is used only with the
SupraSafe 2HSR and SupraSafe 2HSR/TS vaults.
The kit contains a shell housing and mounting
hardware to be cast in place in new masonry or
concrete construction. After construction is completed,
the vault mounts inside the recessed shell housing so
that the small moisture drain hole is on the bottom.
Installation
The mounting kit may be fastened to the inside wall
of a concrete form or set in place during construction
of a masonry wall. Wiring conduit may be connected
through one of several knockout holes in shell housing.
The orientation of the mounting kit requires that the
rebar on the backplate be horizontal. Mount the
housing shell to the backplate so that the tamper switch
adjustment screw is on the left side of the housing.
Important! Care should be taken to insure that the
front of the shell housing, including the cover plate and
screw heads, is ush with nish wall. Shell housing
should be plumbed with a level. Leave cover and
screws in place until vault is ready to be mounted inside.
Four mounting studs are provided for securing the
vault and chain-lid assembly within the housing shell.
1. Place vault in housing shell of mounting kit so
that the vault’s small moisture drain hole is on the
bottom. Align the tamper switch of the vault with
the tamper switch adjustment screw of the housing
shell. The tamper switch adjustment screw has a
slotted head to adjust for proper switch operation.
2. Install washers and nuts onto the two top mounting
studs within the vault. Do not over-tighten mounting
nuts as this may distort outside ange.
3. Slip the chain mounting bracket (attached to the
chain-lid assembly) over the lower right-hand stud
prior to installing the bottom washers and nuts in the
vault. This will permanently attach the lid to the vault.
4. Please contact your re department to install the lid
once the vault has been installed.
Figure 2. Cast-in-Place Mounting Kit and Side View of Installation
Face plate
Rebar
Tamper switch
adjusting screw
Adjusting
screw tamper
switch
Drain hole
Cast-in-Place
Mounting Kit
SupraSafe
2HSR or
2HSR/TS
Vault
Tamper
Switch
(2HSR/TS,
2HS/TS only)

Produkspesifikasjoner

Merke: Kidde
Kategori: Hvelv
Modell: SupraSafe 1

Trenger du hjelp?

Hvis du trenger hjelp med Kidde SupraSafe 1 still et spørsmål nedenfor, og andre brukere vil svare deg




Hvelv Kidde Manualer

Hvelv Manualer

Nyeste Hvelv Manualer