Perlick PKBR24 Bruksanvisning

Les nedenfor 📖 manual på norsk for Perlick PKBR24 (16 sider) i kategorien Ikke kategorisert. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/16
INSTALLATION AND OPERATION INSTRUCTIONS
PERLICK BATCH ROTARY GLASSWASHERS
Warranty Information ........................................ 2
Specifications .................................................... 3
Chemical Specifications
Water Conditioning .............................................. 4
Chemical Concentrations .................................... 4
Start-Up Procedures
Before Starting the Glasswasher ........................ 5
Starting the Glasswasher .................................... 5
Priming the Chemical System ............................. 5
Operational Testing ............................................. 5
Installing Chemical Squeeze Tubes .................... 6
Priming the Chemical Pumps..............................7
Setting the Chemical Controls ............................7
Owners Instructions
Component Identification .................................... 8
Instrument Panel ................................................. 9
Operating the Glasswasher ................................. 9
Washing Glasses ................................................. 9
Chemical Control Panel .................................... 10
Maintenance and Troubleshooting
End of Day Shutdown ....................................... 11
Deliming ............................................................. 11
Troubleshooting .................................................11
Machine Operation & Cycle Sequence ............. 12
Replacement Parts ............................................ 13
Electrical Connection Diagram .......................... 14
Adjusting Chemical Concentrations .................. 15
Calibrating the Chemical System ...................... 15
8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069
Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.Perlick.com
MODEL NOS.
PKBR24
PKBR24L
PKBR24R
PKBR24L
PKBR24
Note:
Some US States may require Energy Star ratings for
Commercial Dishwashers. The specifier or installer is
responsible for knowing their local codes, standards,
and regulatory requirements.
Table of Contents
IMPORTANT INFORMATION
This manual has assist been prepared to you in the
operation Perlick of the Batch Rotary Glasswasher.
We time to that dedicate considerable ensure our
products provide of the highest level customer
satisfaction. service required, dealer If is your can
provide you with a list of qualified service agents.
For your merchandise own protection, never return
for credit without our approval.
We thank you a for selecting Perlick product and assure
you our of continuing interest in your satisfaction.
Product shall be installed in accordance with local codes, or in the
absence of local codes, installed in accordance with the applicable
requirements in the National Electrical Code, NFPA 70, Canadian Electrical
Code (CEC), Part I, CSA C22.1, and Standard for Ventilation Control and
Fire Protection of Commercial Cooking Operations, NFPA 96.
2
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Warranty Information
ONE yEAR LIMITEd wARRANTy
The Perlick Corporation warrants its glasswasher to
be free from defects in material and workmanship,
under normal use and operation, for a period of one
(1) year from the date of initial start-up or eighteen
(18) months from the date of shipment from the
factory, whichever comes first. Perlick® will repair or
replace, at our option, during the warranty period,
any part that may be defective in material and/or
factory workmanship. This warranty is conditioned
upon the customer's maintenance and care as
outlined in the service manual and the return of
the warranty registration card. Warranty repairs will
be performed, free of charge, during Perlick's
®
authorized service agency's normal business hours.
Should the customer require after hours service,
it is the customer's responsibility for any overtime
premium. Machine is warranted only for the
initial place of installation. Removal of machine
automatically terminates this warranty.
Perlick® shall have no liability under this warranty
unless the customer promptly notifies Perlick
® or
its factory authorized service agent of any alleged
defects. All defective parts become the property of
Perlick® and must be returned to Perlick®, or its agent,
at Perlick's® expense, within thirty (30) days from the
date of the part's replacement. Parts replaced within
the warranty carry only the unexpired portions of the
machine's warranty. Not covered by this warranty
are changes (parts and/or labor) necessitated by or
damage resulting from: water conditions, accident,
alteration, improper use, abuse, tampering, improp-
er installation or failure to follow operating and
maintenance procedures. Examples of the forego-
ing, but without limitations are:
1) Damage to machine resulting from excessive
concentrations of chlorine or deliming acid solutions;
2) Use with utilities other than designated on the
glasswasher I.D. plate or owners manual;
3) Improper connection of utility services;
4) Inadequate or excessive water pressure; 5) Leaks
caused by faulty installation; 6) Component failures
caused by water leaks due to faulty installation; 7)
Failure to comply to national and/or local codes; 8)
Failure due to deposits resulting from hard water,
detergents, chlorines, delimers, or improper main-
taining, 9) Resetting breakers or fuse replacement;
10) Adjustments such as thermostats and chemical
pump system; 11) Improper opening of utility supply
valve; 12) Cleaning drain valves, line strainer, spray
nozzles, etc.; 13) Improper installation or malfunc-
tion of chemical dispensing equipment supplied by
others; 14) Failure to provide regular and/or daily
maintenance and cleaning as outlined in this owners
manual.
THIS WARRANTY IS LIMITED TO GLASSWASHERS
INSTALLED WITHIN THE 48 CONTINENTAL
UNITED STATES AND CANADA. IN ALASKA,
HAWAII AND ELSEWHERE OUTSIDE THE
CONTINENTAL U.S. AND CANADA, THIS
WARRANTY IS LIMITED TO REPLACEMENT PARTS
ONLY.
THERE ARE NO OTHER WARRANTIES,
EXPRESSED OR IMPLIED, MADE BY THE
PERLICK CORPORATION FOR ITS GLASSWASHER,
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE AND IN LIEU OF ALL
OTHER OBLIGATIONS OR LIABILITY ON THE
PART OF PERLICK®, INCLUDING LIABILITY FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR FOR LOSS OF PROFITS OR GOODWILL.
NO OTHER WARRANTIES ARE AUTHORIZED ON
BEHALF OF PERLICK®.
RECORD THIS INFORMATION
MODEL NO.__________________________________________________
SERIAL NO.._________________________________________________
INSTALLATION DATE:_________________________________________
3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(R.H. & STD.
UNITS)
HOT WATER INLET
1/2” [13] MALE N.P.T.
(L.H. UNITS)
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(L.H. UNITS)
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(R.H. & STD.
UNITS)
MODEL NOS. PKBR24 PKBR24L PKBR24R
WASH TANK CAPACITY (gals.) 1 1 1
CYCLE TIME (sec.) 120 120 120
WASH TIME (sec.) 60 60 60
SANITIZER TIME (sec.) 35 35 35
GLASSES WASHED PER
HR. (21/ dia.) 2720 720 720
TANK HEATER (watts) 650 650 650
WASH PUMP CAPACITY (gals./min.) 24 24 24
DRAIN FLOW (gals/cycle) 1.67 1.67 1.67
EXHAUST REQUIREMENT None None None
MAXIMUM GLASS HEIGHT 10 10 10
Ship wt lbs. (kg) 225 (103) 225 (103) 225 (103)
ELECTRICAL 120 Volt, 60 Hz., single phase AC. 5.4 amps, furnished with 6 foot power cord and standard
3 prong NEMA style 5-15P.
PLUMBING Hot Water Inlet Connection: 1/2 ” NPTM. Incoming Hot Water: 130–140° F, at 30-60 psi
with a flow rate of 4.0 gal/min. Drain: 11/4 IPS PVC socket connection to include an air gap.
Plumbers Hookup Kit: Includes water hammer arrestor, stop valve and union. Important:
Failure to install the Glasswasher with Plumbers Hookup Kit can damage the hot water
solenoid valve. Machine failure due to improper installation is not covered by Perlicks warranty.
WAT ER HARDNESS Water containing more than 15 GPG will require a water softener. Caution: Parts failure
caused by hard water are not covered under Perlicks warranty.
DETERGENT, SANITIZER and Detergent: A heavy-duty liquid warewashing detergent containing water conditioners.
RINSE AID Chlorine Sanitizer: Any EPA registered chlorine can be used. The EPA marking can be found
on the container label. Rinse Aid: A low-foaming warewashing rinse aid containing water
conditioners. Note: To ensure maximum glasswasher performance. It is important to select
the appropriate detergent and rinse aid for specific water conditions. These chemicals can be
purchased from a local chemical supplier or food service distributor.
OPTIONAL ACCESSORIES • Low Sanitizer shut down kit - #61945 • Glass Rack - #50470-2
Sizes and Specifications
PKBR24 Glasswashers
All plumbing and chemical lines must be routed so that the glasswasher can be pulled out for service.