CyberPower SL950U Bruksanvisning

Les nedenfor 📖 manual på norsk for CyberPower SL950U (2 sider) i kategorien Ikke kategorisert. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/2
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) USB device cable
DETERMINE THE POWER
REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into
the outlet does not exceed the UPS unit’s
rated capacity (700VA/370W for SL700U,
750VA/375W for SL750U, 900VA/450W
for SL900UC and 950VA/510W for
SL950U). If the rated capacities of the unit
are exceeded, an overload condition may
occur and cause the UPS unit to shut down
or the circuit breaker to trip.
2. There are many factors that can aect
the amount of power that your electronic
equipment will require. For optimal system
performance keep the load below 80% of
the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, after receiving a
new UPS, to ensure the battery’s maximum
charge capacity, it is recommended that
you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge
feature. When the UPS is plugged into an
AC outlet, the battery will automatically
charge whether the UPS is turned on or
turned o.
2. With the UPS unit turned o and unplugged,
connect your equipment requiring
battery backup into the battery power
supplied outlets. Plug the other peripheral
equipment (printer, scanner, speakers) into
the full-time surge protection outlets.
DO NOT plug a laser printer, paper
shredder, copier, space heater, vacuum,
sump pump or other large electrical
device into the “Battery and Surge
Protected Outlets”. The power demands
of these devices will overload and possibly
damage the unit.
3. Plug the UPS into a 2-pole, 3-wire grounded
receptacle (wall outlet). Make sure the
wall branch outlet is protected by a fuse
or circuit breaker and does not service
equipment with large electrical demands
(e.g. air conditioner, refrigerator, copier,
etc.). The warranty prohibits the use of
extension cords, outlet strips, and surge
strips.
4. Press the power switch to turn the unit on.
The Power On indicator light will illuminate
green and the unit will “beep” twice.
5. If an overload is detected, an audible alarm
will sound and the unit will emit one long
beep. To correct this, turn the UPS o and
unplug at least one piece of equipment
from the battery power supplied outlets.
Make sure the circuit breaker is depressed
and then turn the UPS on.
6. To maintain optimal battery charge,
leave the UPS plugged into an AC outlet
at all times.
7. To store the UPS for an extended period
of time, cover it and store with the battery
fully charged. While in storage, recharge
the battery every three months to ensure
optimal battery life.
8. Ensure the wall outlet and UPS are located
near the equipment being attached for
proper accessibility.
9. Lay the UPS horizontally or use the key-
hole mounting slots to ax the UPS to the
wall in the proper orientation.
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
SLIM BATTERY BACKUP UPS SERIES
SL700U / SL750U / SL900UC / SL950U
USER MANUAL
FEATURES
1. Power On Switch
2. Power On Indicator (green)
3. Battery and Surge Protected Outlets
4. Full-Time Surge Protection Outlets
5. USB Charging Ports
6. Circuit Breaker
7. USB Port to PC
8. Wiring Fault Indicator (red)
9. Widely-Spaced Outlets
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed
power protection, operation, and performance during the lifetime of the product. Please take a
few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product
loss or theft, and entitles you to free technical support. Register your product now to receive the
benefits of CyberPower ownership.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature and
humidity controlled indoor area free of
conductive contaminants. (Please see
specifications for acceptable temperature
and humidity range).
CAUTION! To reduce the risk of electric shock,
do not remove the cover. There are no user-
serviceable parts inside.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC
input power is disconnected.
CAUTION! The UPS must be connected to an
AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is
not grounded. If you need to de-energize this
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the
unit and unplug it from the AC power source
before installing a computer component.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit over current
protection in accordance with the National
Electric Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
defined in the Standard for the Protection of
Electronic Computer / Data Processing
Equipment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a fire.
The batteries may explode.
CAUTION! Do not open or mutilate batteries.
Released electrolyte is harmful to the skin and
eyes. It may be toxic.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products
for life support or medical applications.
DO NOT use in any circumstance that would
aect operation and safety of life support
equipment, any medical applications or
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock,
do not use with or near an aquarium.
Condensation from the aquarium can cause
the unit to short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do
not use the unit on any transportation such
as airplanes or ships. The eect of shock or
vibration caused during transit and the damp
environment can cause the unit to short out.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
INSTALLING YOUR UPS SYSTEM BASIC OPERATION
1. Power On Switch
To turn the UPS on, press the power button
for approximately 2 seconds - you will hear
a constant tone (1 second) - and release
after a short beep.
To turn the UPS o, press the power button
for approximately 2 seconds - you will hear
a constant tone (1 second) - and release
after two short beeps.
Alarm setting: The audible alarm can be
turned OFF or ON by quickly pressing the
POWER button twice. The default setting
is for the Alarm On. To turn the Alarm O,
quickly press the power button twice. You
will hear two short beeps when the Alarm
is turned o. To turn the Alarm back ON,
quickly press the power button twice. You
will hear a single short beep when the
Alarm is turned on.
*When the Alarm is turned o, there will
be no audible notification when the UPS
reaches a low battery state.
2. Power On Indicator (green)
This LED is illuminated when the utility
power is normal and the UPS outlets are
providing power, free of surges and spikes.
3. Battery and Surge Protected Outlets
The unit has five battery powered
and surge protected outlets to ensure
temporary uninterrupted operation of your
equipment during a power failure.
(DO NOT plug a laser printer, paper
shredder, copier, space heater, vacuum
cleaner, sump pump, or other large
electrical device into the “Battery and
Surge Protected Outlets.” The power
demands of these devices will overload
and possibly damage the unit.)
4. Full-Time Surge Protection Outlets
The unit has three surge suppression outlets.
5. USB Charging Ports
SL750U/SL700U:
Two USB-A ports, 5V 2.4A power output
SL900UC/SL950U:
One USB-A port (5V 2.4A),
One USB-C port (5V 18W)
6. Circuit Breaker
Located on the side of the UPS, the circuit
breaker serves to provide overload and
fault protection.
7. USB Port to PC
The port allows connection and
communication between the USB port on
the computer and the UPS unit. The UPS
communicates its status to the PowerPane
Personal software.
8. Wiring Fault Indicator (red)
This LED indicator will illuminate to
warn the user that a wiring problem exists,
such as bad ground, missing ground or
reversed wiring. If this is illuminated,
disconnect all electrical equipment from
the outlet and have an electrician verify
the outlet is properly wired. The UPS will
not provide surge protection without being
plugged into a grounded and properly
wired wall outlet.
9. Widely-Spaced Outlets
The UPS unit has two widely-spaced
outlets, so AC power adapters can be
plugged into the UPS without overlapping
or blocking adjacent outlets.
2
3 4
9
3
2
4
9
1
5
7
8
6
SYSTEM FUNCTION BLOCK DIAGRAM
DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
6
7 8
5
Input Output
Battery Mode
Normal Mode
EMI
Filter
Surge
Suppressor
Inverter
Charger
AC / DC Battery
Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com
Problem Possible Cause Solution
Full-time surge protection outlets stop
providing power to equipment. Circuit
breaker button is projecting from the
side of the unit.
Circuit breaker has been tripped due to
an overload.
Turn the UPS o and unplug at least one
piece of equipment. Reset the circuit
breaker by depressing the button, and
then turn the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged. Recharge the battery by leaving the
UPS plugged in.
Battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
The UPS will not turn on.
The on/o switch is designed to
prevent damage from rapidly turning
it o and on.
Turn the UPS o. Wait 10 seconds and
then turn the UPS on.
The unit is not connected to an
AC outlet.
The unit must be connected to a
110/120V 50/60Hz outlet.
The battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
Mechanical problem. Contact CyberPower Systems at:
cyberpowersystems.com/support.
The frequency is beyond 47-63Hz
Turn the UPS o. Make sure the
frequency range is within 47-63Hz.
Or you can turn on with battery mode.
PowerPanel® Personal is inactive
(all icons are gray).
The USB cable is not connected.
Connect the USB cable to the UPS unit
and an open USB port on the back of
the computer.
The USB cable is connected to a bad
USB port.
Check for a dierent USB port and plug
the cable in.
The unit is not providing battery power.
Shutdown your computer and turn the
UPS o. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
* LED will flash when UPS alarm is beeping.
POWER ALARM
CONDITION
On O Normal
On*
Beep
twice every
30 seconds
Utility Failure - Battery Mode –
The UPS is providing power to battery power-supplied outlets
from its battery.
On*
Rapid
beeping every
1/2 second
Utility Failure - Low Battery –
The UPS is providing battery power. Rapid beeping indicates
the unit will run out of power soon.
O Constant tone
Overload
Occurs when connected equipment exceeds the rating of battery outlets
of the UPS. Turn the UPS o, unplug at least one piece of equipment
from battery outlets, reset the circuit breaker and turn the unit on.
O Constant tone
Utility Failure –
The frequency is beyond 47-63Hz. The UPS will not turn on
in line mode.
Model SL700U SL750U SL900UC SL950U
Capacity 700VA / 370W 750VA / 375W 900VA / 450W 950VA / 510W
Nominal Input
Voltage 120 Vac
Input Frequency 50/60 Hz +/- 3 Hz
On-Battery
Output Voltage 120Vac +/- 5%
On-Battery
Output Frequency 50Hz/60Hz +/- 1% (auto-sensing)
Max. Load for
UPS Outlets 700VA / 370W 750VA / 375W 900VA / 450W 950VA / 510W
Max. Load for
Full-Time Surge
Protection outlets
12 Amps
On-Battery Output
Wave Form Simulated Sine Wave
Operating
Temperature + 32°F to 104°F / 0°C to 40°C
Operating Relative
Humidity 0 to 95% non-condensing
Size
Width/Height/Depth 12.76 x 5.4 x 2.76 in. / 324 x 138 x 70 mm
Net Weight
(lbs./kg) 6.78 lbs. / 3.07 kg
Typical Battery
Recharge Time 8 hours typical from total discharge
Typical Battery Life 3 to 6 years, depending on number of discharge/recharge cycles
Recommended
Battery Sealed Maintenance Free Lead Acid Battery
Safety Approvals UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B
Advanced Energy-Saving Design
The GreenPower UPS™ has a high-eciency charger, which makes it
the most energy-ecient UPS in its class. The advanced high-frequency
charging system significantly improves charging eciency and conserves
energy. As a result of this advanced design, the GreenPower UPS™ uses
less energy compared to competitive models. The GreenPower UPS™ is
manufactured in accordance with the Restriction on Hazardous Substances
(RoHS) directive making it one of the most environmentally-friendly UPS
systems on the market today.
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
GREEN
POWER UPS
Energy-Saving Technology
Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected
Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of
Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal
and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in
accordance to the local regulations of your state.
WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene,
which is known to the State of California to cause reproductive harm and cancer. For more
information, go to www.P65Warnings.ca.gov.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit dierent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE
FCC COMPLIANCE STATEMENT
© 2024 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.
K01-0000740-03

Produkspesifikasjoner

Merke: CyberPower
Kategori: Ikke kategorisert
Modell: SL950U

Trenger du hjelp?

Hvis du trenger hjelp med CyberPower SL950U still et spørsmål nedenfor, og andre brukere vil svare deg




Ikke kategorisert CyberPower Manualer

Ikke kategorisert Manualer

Nyeste Ikke kategorisert Manualer