DADG-AK-G8
Connection set
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Assembly instructions
8157118
2021-08
[8157120]
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product
è www.festo.com/sp.
Document Product Table of contents
Operating instructions Mini slide DGST
Tab. 1: Applicable documents
2 Safety
2.1 Safety instructions
Only mount the product on components that are in a condition to be safely
operated.
Observe further applicable documents.
Observe tightening torques. Unless otherwise specified, the tolerance is ± 10%.
2.2 Intended use
Connection of compressed air lines axially at the back of the mini slide DGST.
3 Additional information
Contact the regional Festo contact if you have technical problems
è www.festo.com.
Accessories and spare parts è www.festo.com/catalogue.
4 Product Range Overview
4.1 Scope of delivery
1
2
3
Fig.1
1
Air through-guide (1x)
2
O-ring (2x)
3
Socket head screw (2x)
4.2 Not in scope of delivery
45
6
Fig.2
4
Mini slide (1x)
DGST
5
Fitting (2x)
6
Grease (1x)
e.g. LUB-KB1
5 Assembly
1
2
A
6
Fig.3
1. Lightly grease the O-rings with the grease to facilitate assembly.2 6
2. Position the O-rings in the slots [A] of the air through-guide .2 1
The nominal tightening torques are printed on the air through-guide.
Fig. 4: Example: DADG-AK-G8-16
1
3
4
5
B
Fig.5
DADG-AK-G8 DGST-
6 8 10 12 16 20 25
3Screw M3x5 M3x8 M4x8 M5x12 M6x12
[Nm] 1.0 1.2 1.5 3.0 5.0
[B] Air connection
thread
M5 G
[Nm] 0.7 3.0
Tab. 2: Screw size, tightening torques and air connection thread
1. Place the air through-guide on the mini slide .1 4
2. Fasten the air through-guide with the screws to the mini slide .1 3 4
3. Mount the desired fittings on the air connection threads [B].5
Use of one-way flow control valves GRLA on the air connection threads [B]
One-way flow control valves GRLA may restrict the access [C] to the adjustment of
end position on the DGST.
Adjust the external end position before mounting the one-way flow control
valves [D].
Rotate the one-way flow control valves [D] so the access remains clear.
C D
Fig.6