Emko ESD-9950-N Bruksanvisning

Emko Termostat ESD-9950-N

Les nedenfor 📖 manual på norsk for Emko ESD-9950-N (2 sider) i kategorien Termostat. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/2
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
3
2
1
4
5
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
Note1: PID control parameters ( , , , , ,
) are not seen when parameter s set as .
Note2: On Off control parameters ( , ) are not seen
when output control type parameter ( ) s set as .
Note3: Alarm parameters ( , , , , , )
are not seen when output type parameter ( ) s set as .
Note4: Alarm parameters( , , , , ) are not
seen when alarm type parameter ( ) s set as .
Note5: If s d fferent from and user enters on password � �
screen, parameter values are observed but can not be
changed.
Access, Change and Record the Parameter Values
Note : If no operat on for 20 seconds on Parameters Screen, dev ce automat cally return Ma n Screen . � �
Instruct on Manual. ENG ESD-9950-N 01 V05 05/18
Front Panel Def n t on � �
Temperature Un t Ind cator� �
Programm ng Mode Ind cator� �
Status of Control Output 1 (Relay)
Status of Control Output 2 (SSR)
Encoder Button
ESD-9950-N TEMPERATURE CONTROLLER
ESD-9950-N Temperature Controller
- 4 d g ts d splay� �
- Temperature sensor nput (TC / RTD)
- Adjustable Process Offset Value
- Programmable ON/OFF, P, PI, PD ve PID control types
- Adaptat on of PID coeff c ents to the system by Auto Tune/Self Tune � �
- Programmable control and alarm funct ons for control outputs
ESD-9950-N temperature controllers are des gned for measur ng and � �
controll ng a temperature value n ndustry. They can be used n many � �
appl cat ons w th the r TC and RTD temperature measurement nput, mult -� �
funct on control outputs, programmable control and alarm funct ons.� �
They are ma nly used n glass, plast c, petro-chem stry, text le, automot ve and � �
mach ne product on ndustr es. Accurate and advanced controll ng s � � � �
performed w th selectable ON-OFF, P, PI, PD, PID, Self Tune PID, Auto Tune
PID funct ons.
SPECIFICATIONS
INPUT
Process Input: TC/RTD
Thermocouple (TC): J, K, R, S, T and L (IEC584.1)(ITS90)
Thermores stance (RTD): Cu-50 and Pt100 ( IEC 751) (ITS90)
Measurement Range: Please refer to parameter n parameters sect on.� �
Accuracy: ± 0.25% of scale for thermocouple and thermores stance.
Cold Junct on Compensat on: Automat cally ±0.1°C/1°C
L ne Compensat on: Max mum 10 Ohm
Sensor Break Protect on: Upscale
Sampl ng Cycle: 0.1 second
CONTROL
Control Forms: ON/OFF, P, PI, PD veya PID (Control form can be
programmed by the user.)
OUTPUT
Process Output: Relay(7A@250V at res st ve load) or SSR Dr ver Output V� �
(Max mum 10mA, Max. 17V )Z
Alarm Output:Relay (7A@250V at res st ve load)V� �
DISPLAY
Temperature D splay: 16 mm Red 4 d g ts LED D splay� �
Led Ind cators: O1 (Relay Process Output Status LED), O2 (SSR Process
Output Status LED), P(Programm ng Mode LED),S(Set Value LED),ºC, ºF LEDs
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operat ng Temperature: 0...50ºC
Hum d ty :� � 0-90%RH (none condens ng)
Protect on Class: IP65 at front , IP20 at rear
We ght: 350 gr.
D mens on: 96 x 96 mm, Depth: 100 mm
Panel CutOut: 92 x 92 mm
SUPPLY VOLTAGE
230V (±15%) 50/60Hz - 3VAV
115V (±15%) 50/60Hz - 3VAV
24V (±15%) 50/60Hz - 3VAV
Must be determ ned � �n order.
Panel Mount ng
Electr cal W r ngs � �
To reduce the effect of electr cal no se on dev ce, low voltage l ne (espec ally sensor � �
� � nput cables) w r ng must be separately from h gh current and voltage l ne. If
poss ble, use sh elded cable abd sh eld must be connected to ground only one s de.� �
Panel Cut-out
92 mm / 3.62 nch(m n)� �
92 mm / 3.62 nch(m n)� �
129 mm / 5.08 nch(m n)� �
129 mm / 5.08 nch(m n)� �
Note : If no operat on for 10 seconds, dev ce automat cally ex ts from Set Value Screen w thout sav ng the value. � �
Access and Change Set Value
Press encoder button
to observe the set value.
Turn left encoder button
to decrease or turn r ght
to ncrease the set value.
Press encoder button
to save new set value
and return the ma n screen
ESD-995 0-N
ESD-995 0-N
Ma n Screen
ESD-995 0-N
Ma n Screen
ESD-995 0-N
Set Value Screen Set Value Screen
Press encoder
button
dur ng 5 seconds.
Approve password
w th encoder button.
Enter the password
w th encoder button.
Turn left encoder button
to decrease or turn r ght
to ncrease value.
If no pr vacy lock dent f cat on � �
Parameters Screen w ll be
observed. If pr vacy lock s � �
� � dent f ed, w ll be
observed. Press encoder button
to access Password Screen.
ESD-995 0-N
SET
Ma n Screen
SET
Password Screen
SET
Password Screen Parameters Screen
If Parameters Screen is
active, "P" led blinks. To
observe previous
parameter, turn encoder
button left. To observe
next parameter, turn
encoder button right.
Press encoder button to
observe parameter value.
Parameters Screen
ESD-995 0-N
Parameters Screen
ESD-995 0-N
Parameters Screen
ESD-995 0-N
Parameters Screen
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Press encoder button
to observe
the parameter value.
ESD-995 0-N
Parameters Screen
To increase parameter
value, turn encoder
button right. Press
encoder button to save.
To decrease parameter
value, turn encoder
button left. Press encoder
button to save.
D mens ons� �
96 mm / 3.78 nch
96 mm / 3.78 nch
84 mm / 3.31 nch
11.5 1mm / 0.45 nch
Max mum 15 mm / 0.59 nch� �
1- Before mount ng the dev ce n your panel, � �
make sure that the cutouts s of the r ght � �
s ze.
2- Check front panel gasket pos t on.� �
3- Insert the dev ce through the cutout. If the
mount ng clamps are on the un t, put out � �
them
before nsert ng the un t to the panel.� �
4- Insert the mount ng clamps to the two of
des gnated holes that located on four s des � �
of dev ce.
5- Drag the mount ng clamps n d rect on 5 � �
unt l the dev ce completely mmob le w th n � �
the panel.
6- In order to remove dev ce push on the
mount ng clamp as shown w th arrow 6 and � �
pull back.
Parameter Values Screen Parameter Values Screen
Temperature Un t Ind cator� �
Set Value Ind cator
SETSET
°C
°F
P
O1
O2
+
++
S
SET
°C
°F
P
O1
O2
+
++
S
SET
°C
°F
P
O1
O2
+
++
S
SET SET
°C
°F
P
O1
O2
+
++
S
Relay Output
TC
PT-100
45 10 11 12 13 14 15
7A@250VV
6 7 8 9
NCCNO
-
+
10mA@17VZ
SSR Dr ver
Output
ESD-9950-N
CAT II
O2
(Process
Output 2)
O1
(Process Output 1
or
Alarm Output)
Process Input
(Analog Input)
Supply
Voltage
Supply
Voltage
Sw tch
N
L
1A T
Fuse
N
L
Time
Time
Temperature
Control Output
Temperature
Set Value
Temperature
Hysteresis
Adjustment of Hysteres s Value for ON/OFF Control
In ON/OFF control algor thm, temperature value s tr ed to keep equal to set � �
value by open ng or clos ng completely last control element. ON/OFF controlled � �
system, temperature value osc llates cont nuously. Temperature value’s � �
osc llat on per od or ampl tude around set value changes accord ng to controlled � �
system. For reduc ng osc llat on per od of temperature value, a threshold zone � �
� �s formed below or around set value and th s zone s named hysteres s. Act on
of control output s descr bed w th f gures below. � �
Before comm ss on ng the dev ce, parameters must be set n� �
accordance w th des red use. Incomplete or ncorrect conf gurat on � �
can cause dangerous st uat ons.� �
Because of l m ted mechan cal l fe of relay output contact, SSR output � �
� � s recommended wh ch the dev ce use PID control algor tm. The
dev ce w th ON/OFF control algor tm, hysteres s parameter must be � �
set a su table value for your system, to avo d too much relay sw tch ng. � �
V Vac,
Z Vdc,
W Vdc or Vac can be appl ed.→ �
Other Informat ons
Manufacturer Informat on:
a
Emko Elektron k Sanay ve T caret A. . � � Ş
Dem rta Organ ze Sanay Bölges Karanf l Sk. No:6 16369 � ş
BURSA/TURKEY
a
Phone : +90 224 261 1900
Fax : +90 224 261 1912
a
Repa r and Ma ntenance Serv ce Informat on:� �
a
Emko Elektron k Sanay ve T caret A. . � � Ş
Dem rta Organ ze Sanay Bölges Karanf l Sk. No:6 16369 � ş
BURSA/TURKEY
a
Phone : +90 224 261 1900
Fax : +90 224 261 1912
Customer
3
4
5
9
24V (±%15) 50/60HzV
115V (±%15) 50/60HzV
230V (±%15) 50/60HzV
224V (±%15) 50/60HzW
10 - 30 V Z8
Supply VoltageA
Input Type
BC
Conf gurable20
Scale
See Parameters ( )
Output-1 (Process or Alarm)E
*Relay Output (7A@250V at Res st ve Load) (NO,NC,C) V� �
1
Output-2FG
*SSR Dr ver Output (Max.10mA,17V ) Z
02
Order ng Informat ons� �
ESD-9950-N(96x96 DIN 1/4)
20
0 1
02 00
* If Process Output Type Parameter ( ) s chosen as Relay ( ) from
Parameters, SSR Output w ll be pass ve.� �
If Process Output Type Parameter ( ) s chosen as SSR ( ) from
Parameters, Relay Output w ll be set as Alarm Output.
Dev at on Range� �
H gh Alarm
Process
Set
Alarm
Set
Process
Set
Alarm
Hysteres s
Alarm
Output
Process Value
Dev at on Range� �
Alarm
Process
Set
Alarm
Set
Process
Set
Process
Set
Alarm
Set
Alarm
Hysteres s
Alarm
Hysteres s
Alarm
Output
Process Value
Parameters Descr pt ons� �
: Process nput type select on parameter. (Default: )� �
: J type (Fe,Cu,N ) Thermocouple; -200ºC,900ºC ; -328ºF,1652ºF
: J type (Fe,Cu,N ) Thermocouple; -199.9ºC,900.0ºC ; -199.9ºF,999.9ºF
: K type (N ,Cr,N ) Thermocouple; -200ºC,1300ºC ; -328ºF,2372ºF� �
: K type (N ,Cr,N ) Thermocouple; -199.9ºC,999.9ºC ; -199.9ºF,999.9ºF� �
: R type (Pt13%RhPt) Thermocouple; 0ºC,1700ºC ; 32ºF,3092ºF
: R type (Pt13%RhPt) Thermocouple; 0.0ºC,999.9ºC ; 32.0ºF,999.9ºF
: S type (Pt10%RhPt) Thermocouple; 0ºC,1700ºC ; 32ºF,3092ºF
: S type (Pt10%RhPt) Thermocouple; 0.0ºC,999.9ºC ; 32.0ºF,999.9ºF
: T type (Cu,Cu,N ) Thermocouple; -199ºC,400ºC ; -199ºF,752ºF
: T type (Cu,Cu,N ) Thermocouple; -199.0ºC,400.0ºC ; -199.0ºF,752.0ºF
: L type (N ,Cr,Co/N ,Fe,Mn,Cu) Thermocouple; -150ºC,800ºC; -199ºF,999ºF� �
: L type (N ,Cr,Co/N ,Fe,Mn,Cu) Thermocouple; -150.0ºC,800.0ºC;-199.0ºF,999.0ºF� �
: Cu-50 Thermores stance; -199ºC,200ºC ; -199ºF,392ºF
: Cu-50 Thermores stance; -199.0ºC,200.0ºC ; -199.0ºF,392.0ºF
: PT100 Thermores stance; -200ºC,650ºC ; -328ºF,1202ºF
: PT100 Thermores stance; -199.9ºC,650.0ºC ; -199.9ºF,999.9ºF
: Un t select on parameter. or can be chosen. (Default: )� �
: Operat on scale m n mum(Low L m t) value. It changes accord ng to � �
the process nput type and scale. (Default: -200)
: Operat on scale max mum(H gh L m t) value. It changes accord ng to � �
the process nput type and scale. (Default: 900)
: Process set value low l m t parameter. It can be adjusted between � �
Operat on Scale M n mum( ) and Process Set Value H gh L m t( ). � �
(Default: -200)
: Process set value h gh l m t parameter. It can be adjusted between � �
Process Set Value Low L m t( ) and Operat on Scale Max mum( ).� �
(Default: 900)
: Process offset value. It can be adjusted as a degree( or ),
from -10% of scale to 10% of scale. It s added to the process d splay value. � �
(Default: 0)
: Process output type. Process output can be selected Relay( ) or
SSR( ). (Default: )
: Output control type select on. It can be selected or .
(Default: )
: Hysteres s value. It can be adjusted from 1º(po nt representat on s � �
0.1º) to 20º. (Default: 3)
: M n mum ON/OFF control output t me parameter. It can be adjusted � �
from 0 to 60 seconds. (Default: 0)
: Proport onal band (P) value. It can be adjusted from %1.0 to %100.0.
(Default: 10.0)
: Proport onal Per od (Output Control Per od). If control output s SSR, � �
It can be adjusted from 0.5 to 150.0 seconds. If control output s Relay, It
can be adjusted 60.0 to 150.0 seconds. (Default: 10.0)
: Proport onal Offset value. Th s parameter s used for sh ft ng the � �
proport onal band. It can be adjusted as a degree( or ), from (-Operat on � �
Scale Max mum /2) to (Operat on Scale Max mum /2). (Default: 0) � �
: Integral T me. It can be adjusted from 0 to 3600 seconds.
(Default: 100)
: Der vat ve T me. It can be adjusted from 0.0 to 999.9 seconds. � �
(Default: 25.0)
: If tune parameter s set as or , dev ce starts to calculate� �
PID parameters automat cally. (Default: )
: Dev ce does not calculate PID parameters.
: Step Response Tun ng operat on.� �
: L m t Cycle Tun ng operat on. � �
: Alarm type select on.(Default: )
: Alarm set value parameter. It can be adjusted between Operat on
Scale M n mum to Operat on Scale Max mum. (Default: 300)� �
: Alarm hysteres s value. It can be adjusted from 1º (po nt� �
representat on: 0.1º) to 50% of scale. (Default: 3)
: Alarm on delay t me. It can be adjusted from 0 to 9999 seconds.
(Default: 0)
: Alarm off delay t me. It can be adjusted from 0 to 9999 seconds.
(Default: 0)
: Alarm open ng delay t me. It can be adjusted from 0 to 9999 seconds. � �
(Default: 0)
: Password for access ng to the parameters sect on. It can be adjusted � �
from 0 to 9999. If parameter value s , password screen s not seen. If � �
parameter value s d fferent from and ;� �
-If user enters d fferent value from saved value, dev ce w ll return to ma n � �
screen automat cally.
-If user enters , all parameters can be observed except . But
dev ce does not allow to do any changes n parameters. (Default: )� �
Temperature
Control Output
Temperature
Set Value
Temperature
ON/OFF
Control Form
with
Hysteresis
Alarm Types
Alarm
Set
Alarm
Hysteres s
Alarm
Output
Process Value
Process High
Alarm
Process Low
Alarm Alarm
Hysteres s
Alarm
Set
Alarm
Output
Process Value
Dev at on H gh � �
Alarm
Process
Set
Process
Set
Alarm
Set
Alarm
Hysteres s
Alarm
Output
Process Value
Dev at on Band� �
Alarm
Process
Set
Alarm
Set
Process
Set
Process
Set
Alarm
Set
Alarm
Hysteres s
Alarm
Hysteres s
Alarm
Output
Process Value
Dev at on Low � �
Alarm
Alarm
Output
Process Value
Process
Set
Process
Set
Alarm
Set
Alarm
Hysteres s
Tune Operat on
Start ng the Tune operat on� �
1- Enter the parameter and select or . Observe that bl nks.
(If s selected and start cond t ons are not okay for Tune operat on, � �
bl nks dur ng 10 seconds.)� �
2- Dev ce calculates PID control coeff c ents and sets the process value to � �
wanted value.
Cancell ng tune operat on:� �
1- If sensor breaks;
2- If tune operat on can not be completed n 8 hours;� �
3- Wh le tune operat on s runn ng, f process value becomes greater than � �
process set value;
4- Wh le tune operat on s runn ng, f user changes the process set value; � �
6- Wh le tune operat on s runn ng, f user changes the parameter n menu; � �
Then tune operat on s canceled and dev ce cont nues to run w th former PID � �
parameters w thout chang ng PID parameters.� �
Error Messages
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
Sensor fa lure n analog nputs.If there s no � �
sensor connect on or the value that s read from � �
the analog nput goes out of the dev ce scale, � �
warn ng s observed.� �
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
If one of the alarm types n the alarm parameter
( ) s selected and the alarm cond t on has � �
occurred, the temperature value s d splayed � �
alternately w th message on d splay .� �
In package,
-One piece unit
-Two pieces mounting clamp
-One piece instruciton manual
A visual inspection of this product for possible damage occured
during shipment is recommended before installation. It is your
responsibility to ensure that quali ed mechanical and electrical
technicians install this product.
If there is danger of serious accident resulting from a failure or
defect in this unit, power o the system and the electrical
connection of the device from the system.
The unit is normally supplied without a power switch or a fuse.
Use power switch and fuse as required.
Be sure to use the rated power supply voltage to protect the unit
against damage and to prevent failure.
Keep the power o until all of the wiring is completed so that
electric shock and trouble with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit.
Tampering with the unit may results in malfunction, electric shock
or re.
Do not use the unit in combustible or explosive gaseous
atmospheres. During the equipment is put in hole on the metal
panel while mechanical installation some metal burrs can cause
injury on hands, you must be careful.
Montage of the product on a system must be done with it's
mounting clamp. Do not do the montage of the device with
inappropriate mounting clamp. Be sure that device will not fall
while doing the montage.
It is your responsibility if this equipment is used in a manner not
speci ed in this instruction manual.
Before beg nn ng nstallat on of th s product, please read � �
the nstruct on manual and warn ngs below carefully.� �
Installat on
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
Tune fa lure. If s selected n PID Tune � �
Parameter( ) and start cond t ons are not okay � �
for Tune operat on, the temperature value s � �
d splayed alternately w th message on � �
d splay dur ng 10 seconds.� �
Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects
in material and workmanship. This warranty is provided for a period of two
years. The warranty period starts from the delivery date.
This warranty is in force if duty and responsibilities which are
determined in warranty document and instruct on manual performs by the
customer completely.
Ma ntenance
Repairs should only be performed by trained and specialized personnel. Cut
power to the device before accessing internal parts. Do not clean the case
with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a
cloth dampened in ethyl alcohol or water to clean the external plastic
case.

Produkspesifikasjoner

Merke: Emko
Kategori: Termostat
Modell: ESD-9950-N

Trenger du hjelp?

Hvis du trenger hjelp med Emko ESD-9950-N still et spørsmål nedenfor, og andre brukere vil svare deg




Termostat Emko Manualer

Termostat Manualer

Nyeste Termostat Manualer