Fredrick Ramond FR45608BNI Bruksanvisning
Fredrick Ramond
Lampe
FR45608BNI
Les nedenfor 📖 manual på norsk for Fredrick Ramond FR45608BNI (3 sider) i kategorien Lampe. Denne guiden var nyttig for 4 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/3

FR45608BNI/FBZ
MIME
ASSEMBLY I N STR UC TIONS
Assembly of this fixture will be accomplished by first assembling the main body,
installing the mounting hardware to the junction box, hanging the fixture and then
installing the shade and crystals.
SAFETY WARNING: Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
STEP 1
1
STEP 2 Refer to Hanging Instruction Sheet to hang fixture. Then refer[FRIS19]
back to this sheet to continue installation of this fixture.
STEP 3
1
2
3
[DRAWING 1]
Bulbs: 6-60W CAND. Replacement Parts: SHADE:
11.23.09
Slip center stem with top main body along wire and thread onto threaded(4) (b)
tube located on the top of socket body assembly .(t) (a)
Slip loop along wire and thread onto top of fixture.(5)
Spread arms until they are 60 degrees apar t.(b)
Fixture is ready for installation.
2
3
4
Take shade and line up holes in tabs with the holes in (7) (d)
end of arms . Shade tab shold be on top of the arm. (b)
1Slip center col
main body with the three arms see (b) - DRAWING 1.
umn
(4) along wire and thread onto swivel (s) located on the top
: R45608SH (BNI FINISH),
R455608AMBSH ( fbz FINISH),
R45602CRY-A
Slip ball knob stud through hole in shade tab and thread it into (8)
arm . Repeat process with the remaining shade tabs. (b)
attach crystals to loop (9) (e).
Next thread knob onto threaded tube . Then(10) (f)
4
8
d
ce
5
b
e
e
9
7
9
t
a
f
10

HANGING INSTRUCTIONS
FRIS19
SAFETY WARNING: Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
STEP 1
Shut off electrical current before starting. If the fixture you are replacing is1
turned on and off by a wall switch, simply turn the switch off. If not, remove the
appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
STEP 2
STEP 3
Taking the chain, determine the length you require to hang the fixture.1
Attach one end of the chain to the top loop of the fixture - see .2 Drawing 2
Now slip loop collar and canopy onto chain .3 (6) (B) (C)
4 Attach other end of chain to loop . Get assistance for this step since fixture (5)
may be heavy and difficult to hold while attaching the chain.
STEP 4
1 Unwrap supply wire and ground wire and weave them up through the chain.
Slip supply wire and ground wire through center of loop2 (5).
Connect ground wire to mounting strap using green ground screw .3 (1) (GS)
4 Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet and follow all instructions to make all necessary [FRIS18]
wiring connections.
Slip canopy up firmly against the ceiling and secure by turning the threaded 5
loop collar onto loop until tight.(6) (5)
[DRAWING 1]
[DRAWING 2]
1
2
A
4
B5
C
6
weave supply wire and
ground wire through chain
GS
3c
3b
3a
half of threaded area
exposed
1 Fasten mounting strap to outlet box with the two 8-32 screws (not provide) (1) (A)
(2) Drawing 1. -see
2 (3a) (3b) (4) Thread 2 - hex nuts and onto threaded tubing .
3 (4) (5) Thread one end of threaded tubing into loop a minimum of 1/2” to 3/4”.
Thighten hexnut against loop to lock loop in position.(3a) (5)
4 (4) Thread other end of threaded tube into mounting strap approximately 1/2”.
5 (B) (5) Slip canopy over loop and adjust height of loop so half of the threaded area
on the loop is exposed - see below. After loop height is adjusted, thigtenDrawing 2
hex nut up against mounting strap, tighten against mounting strap to lock (3b)
in position.
6 (1) (A) (3c) Remove mounting strap from junction box , and thread third hex nut onto
end of threaded tube above the mounting strap , tighten against mounting strap (4), (1)
to lock assembly in position.
7 Remount mounting strap to junction box.
021714

WIRING AND GROUNDING INSTRUCTIONS
SAFETY WARNING: Read wiring and grounding instructions
[FRIS 18] and any additional directions. Turn power supply off during installation. If new
wiring is required, consult a qualified electrician or local authorities for code require-
ments.
STEP 1 WIRING INSTRUCTIONS
Indoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth, unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 1 or 2.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Please refer to the grounding instructions below to complete all electrical
connections.
Outdoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 2 or 3.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a fixture
mounting platform specially.
4 Please refer to the grounding instructions below to complete all electrical
connections.
STEP 2 GROUNDING INSTRUCTIONS
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (e) (typically copper or green plastic coated) to the fixture mounting strap
(1) with the ground screw (2) - See Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (e) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - See Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (e) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal - See
Drawing 3.
[drawing 1]
[drawing 2]
[drawing 3]
1.30.08
a c e
1
b d
supply wire
xture leads
twist-on
connectors
2
a c
e
e
1
b d
2
a c e
e
b d
twist-on
connectors
supply wire
xture leads
supply wire
xture leads
twist-on
connectors
FRIS18
Produkspesifikasjoner
Merke: | Fredrick Ramond |
Kategori: | Lampe |
Modell: | FR45608BNI |
Trenger du hjelp?
Hvis du trenger hjelp med Fredrick Ramond FR45608BNI still et spørsmål nedenfor, og andre brukere vil svare deg
Lampe Fredrick Ramond Manualer

15 Oktober 2024

15 Oktober 2024
Lampe Manualer
- Lampe Ledlenser
- Lampe AFX
- Lampe Hama
- Lampe Neewer
- Lampe Hazet
- Lampe Philips
- Lampe Topeak
- Lampe Schwaiger
- Lampe Godox
- Lampe IKEA
- Lampe Samsung
- Lampe Sony
- Lampe Xiaomi
- Lampe Lutec
- Lampe Golden Lighting
- Lampe ET2
- Lampe Quoizel
- Lampe Crystorama
- Lampe Brennenstuhl
- Lampe Dainolite
- Lampe EMOS
- Lampe Nanlite
- Lampe BeamZ
- Lampe Livoo
- Lampe Flex
- Lampe Maxim
- Lampe Brandson
- Lampe Maginon
- Lampe Ansmann
- Lampe Makita
- Lampe Intermatic
- Lampe V-Tac
- Lampe JBL
- Lampe Nedis
- Lampe Elation
- Lampe Chauvet
- Lampe Karma
- Lampe Ridem
- Lampe Dedra
- Lampe Black Diamond
- Lampe Powerplus
- Lampe Ozito
- Lampe BenQ
- Lampe Hansa
- Lampe Livarno Lux
- Lampe Eurolite
- Lampe Casalux
- Lampe American DJ
- Lampe Profoto
- Lampe Petzl
- Lampe Gravity
- Lampe AVM
- Lampe Impact
- Lampe Olight
- Lampe Vimar
- Lampe Genaray
- Lampe Altman
- Lampe Setti+
- Lampe Kanlux
- Lampe Xline
- Lampe ARRI
- Lampe Osram
- Lampe Zhiyun
- Lampe Honeywell
- Lampe Perfect Christmans
- Lampe XCell
- Lampe Physa
- Lampe Jinbei
- Lampe Apa
- Lampe Bolt
- Lampe Heitronic
- Lampe HQ Power
- Lampe Currey & Company
- Lampe Deko-Light
- Lampe Angler
- Lampe Raya
- Lampe Livex Lighting
- Lampe Hinkley Lighting
- Lampe Norwell
- Lampe Ranex
- Lampe COLBOR
- Lampe Lucide
- Lampe Nicols
- Lampe Dorr
- Lampe Pixel
- Lampe Silva
- Lampe Allegri
- Lampe Rotolight
Nyeste Lampe Manualer

14 Mars 2025

14 Mars 2025

14 Mars 2025

14 Mars 2025

14 Mars 2025

13 Mars 2025

13 Mars 2025

13 Mars 2025

13 Mars 2025

13 Mars 2025